17
PROBLEM CHECKING AND METHOD OF PCB
- IfyoupluginthepowercordandturnPowerS/Won,memorizeddataisdisplayed.
Ifanydataisnotdisplayed,checkthefollowings.
Thermistor Check
CheckVoltageatPin#1and#2ofCN3
TesterCheck=DC2.7V
Ifitready5V,checkifitsconnectorisengagedproperly.
Water Sensor Check
CheckVoltageandFrequencyatPin#3and#2ofCN3
Resetwaterlevel=DC2.5V,25.0KHz
CheckVoltageandFrequencyatPin#4and#2ofCN3
Resetwaterlevel=DC2.5V,25.0KHz
WF361*/WF363*
WF365*/WF364*
TROUBLE SHOOTING
Toavoidriskofelectricalshock,personalinjuryordeath;disconnectpowertowasher
beforeservicing,unlesstestingrequirespower.
WARNING