Error Type
Error Mode
Causes Corrective Actions Description of Photo
LED LCD
WaterSupply
Error
nF
Low W a ter Pressure
ERROR!
• Watersupplyvaluefault
• MainPCBfault
• Freezinginthewinter
season
• Ifthewatersupplyvalvehasawire
disconnected,replaceit.
• Checkwhetherthewatersupplyvalve
iscloggedwithforeignmaterialand
whetherwaterissuppliedcontinually.
• Checkwhethernowaterissupplied
becauseoffreezinginthewinter
season.
• IfthePBArelayoperatesabnormally,
replacethePBA.
1. Checktheresistanceforthe
watersupplyvalve.
- Resistance:1.0to2.0kΩ
betweentheterminalsofthe
watersupplyvalve.
2. Checkwhetherthereis
foreignmaterialinthewater
supplyvalvelter.
3. Ifthewatersupplyvalvelter
isclogged,cleanlter.
Drain Error nd
• Freezinginthewinter
season
• Foreignmaterialsinthe
drainpump
• Poorphysicalconnection
• Drainpumpfault
• MainPCBfault
• Ifthedrainpumprevolutionsare
restrainedduetofreezinginthewinter
season,checkthemethodtoremove
thefreezingandremoveasdirected.
• Checkwhethertherevolutionsof
thedrainpumpmotorarerestrained
byforeignmaterial,andremoveas
directed.
• CheckthewireconnectorsonMain
PCBandDrainPumpASSY.The
connectororwiremayhavepoor
physicalconnection.
• Checkthedrainpumpresistance.
Checkthedrainpump
resistance.
(Resistance20°C:14.2ohm
±7%)
Communication
Error
AE
Electronic Control Problem
ERROR!
• Thesignalsbetweenthe
subandmainPBAsare
notsensed.
• Incorrectwireconnections
betweenthesubandmain
PBAs.
• Checkthewireconnectionsand
terminalcontactsbetweenthesuband
main PBAs.
• Checkfordisconnectedwires.
• CheckwhetherthesubPBAisshort-
circuitedbecauseofmoisture.
• IfthemainPBA’scommunication
circuitisfaulty,replaceit.
-