Troubleshooting _ 31
No.
Information
Type
Information
Code
Causes Corrective Actions
10 WaterLeakage
LC
LC1
- Heaterengagementfault.(outofplace)
- Theairhoseisoutofplaceandwaterleakage
occursduringthespincycle.
- Thetubbackatthesafetyboltsxingpartis
broken.
- Waterleakageoccursatthefrontwithfoaming
becauseoftoomuchdetergent.
- Waterleakageoccursbecausetheconnecting
hosetothedetergentdrawerisconnected
incorrectly.
- Thedrainpumpltercoverisengagedincorrectly.
- Waterleakageoccursatthedrainhose.
- Theductcondensingholdingscrewsareworn.
- Thenozzle-diaphragmisengagedintheopposite
directionortherubberpackagingisomitted.
- Waterleakageoccursbecausethescrewsthat
holdthetubbackandfrontinplacearefastened
incorrectly.
- Theleakagesensorisfaulty.
•CheckWaterLeakage
•DVCASEforeignmaterial
occurs
•Leakageoftheproductinside
thehoseandpartsmolded
problem
11 OVERFLOW
OC
OF
- Waterissuppliedcontinuallybecausethewater
leveldetectiondoesnotwork.
- Becausethedrainhoseiscloggedandthereisan
injectionerror(atanarrowsection),thewaterlevel
detectiondoesnotworkandwaterissupplied
continually.
- Waterissuppliedcontinuallybecauseoffreezing
orbecausethereisforeignmaterialinthewater
supplyvalve.
- Thismayoccurwhenthewaterlevelsensoris
degraded.
•Waterlevelsensorfault
•Freezingbywinterseason
12
Temperature
Sensor
TC1
- Thewashingheaterinthetubhasanerror.
(Contacterror,temperaturesensorfault)
- Theconnectorisconnectedincorrectlyoris
disconnected.
- Ifthewaterlevelsensoroperateswithoutwater
becausethewaterisfrozenorforanyother
reasonandthetemperaturesensorengagedat
thebottomtopreventoverheatingforthewashing
heaterdetectsatemperatureof100to150˚C,the
washingmachineturnstheinputpoweroff.
•Washingtemperaturesensor
check
•Drytemperaturesensorcheck
•Drycondensingtemperature
sensorcheck
•Problemscausedbythemain
PCBfault
•Problemscausedbythe
freezinginwinter
TC2
- Thetemperaturesensorfortheductassyfan
housingisfaulty.(Asensorfaultsuchasan
internalshort-circuitorwiredisconnection)
- Theconnectorisoutofplaceorhasacontact
error.
TC3
- OccurDuctcondensingtemperaturesensor
whenisOPEN
- Thisoccurswhentheductcondensing
temperaturesensorhasawiredisconnectedoris
short-circuited.
13
Detergent
Drawer
SDC
- DetergentDrawercontactfault
•DetergentdrawerOpenand
closeitagain.
- ASSYPUMPDRAINfault
•Disassembledetergentdrawer,
cleanthehousingconnector,
andtryitagain.Ifthisdoesnot
help,changeassypumpdrain
thatisSub-Materialsofassy
drawer.
14
Detergent
DrawerMotor
6C
- Autodetergentdispensemotorconstrain
- Autodetergentdispensemotorwiring
- Autodetergentdispensemotornotoperate
•Checkmotoroperationby
pressingthelaundrywhenyou
enterautodetergentdispenser.
•IfnotoperationchangeASSY
PUMPDRAIN
WW22N6850NX-A2_SM.indb 31 2018/2/1 17:15:49