76 
 
9.9 Brightness/Color Calibration 
Online Calibration 
Online  calibration  is  that  NovaCLB  (calibration  software)  connect  NovaLCT  through 
network for calibration of LED displays.   
It supports single-screen mode and combined-screen mode. 
 
l    Current Serial Port 
This is the serial port through which the LED display to be calibrated is connected to the 
computer. 
l    Current Screen 
The LED displays connected to the computer will be list in this panel. Select the LED 
display to be calibrated from the list. 
l    Local IP 
This is the IP address that NovaLCT listens to. It is actually an IP of the computer on 
which NovaLCT is running.   
l    Port 
This is the port that NovaLCT listens to. 
l    Reconnect 
Click this button to terminate the current listening process and start a new listen process 
using the settings of Local IP and Port. 
l    Communication Log 
Records of the communication between NovaCLB and NovaLCT are listed is this panel. 
l    Enable Calibration 
This option is to enable or disable LED display calibration using calibration coefficients. 
l    Save button in the Enable/Disable Calibration panel 
Click this button to save the calibration switch status (enable or disable) to the hardware. 
l    Save button in the communication log panel 
Click this button to save the communication log to a text file.