CDR-10039
D
DRAWING SIZE
DRAWN BY
PRODUCT DESCRIPTION
NEXT ASSEMBLY
ORIGINATION DATE
SCALE
TERRY.KERR
9/9/2014NONE
6801M-20
ENERGYLINE - SWITCH CONTROLS
CDR-10039
D
B
A
8
6
4
1
2
3
5
7
UNITS
PROJECTION
INCHES
REVISIONS
MATERIAL
FINISH
DRAWING NO.
DRAWING NO.
DESCRIPTION
SE
SE
ECO NO. DATENO.
REV BY
000
001 11/26/2014
9/9/2014ST510099
ST510335
TK
TK
THIS DOCUMENT AND ALL PREVIOUS ISSUES ARE THE SECRET AND CONFIDENTIAL PROPERTY OF
S&C ELECTRIC COMPANY ("S&C"), 6601 NORTH RIDGE BOULEVARD, CHICAGO, ILLINOIS, AND NEITHER
RECEIPT NOR POSSESSION THEREOF INFERS OR TRANSFERS ANY RIGHT IN OR LICENSE TO USE
THIS DOCUMENT, THE SU
BJECT MATTER THEREOF, OR ANY DESIGN OR TECHNICAL INFORMATION
SHOWN THEREON; OR ANY RIGHT TO REPRODUCE THIS DOCUMENT OR ANY PART THEREOF,
NEITHER THIS DOCUMENT NOR ANY INFORMATION CONTAINED THEREIN MAY BE COPIED, REPRODUCED,
OR OTHERWISE USED OR DISCLOSED TO ANY OTHER PARTY WITHOUT FIRST OBTAINING THE
EXPRESS WRITTEN PERMISSION OF S&C. THIS DOCUMENT IS PROVIDED UNDER THE EXP
RESS
CONDITION THAT IT WILL BE HELD IN CONFIDENCE BY THE RECIPIENT, THAT IT IS SUBJECT TO
RETURN UPON DEMAND, AND THAT IT WILL NOT BE USED IN ANY WAY DETRIMENTAL TO S&C.
PROPRIETARY STATEMENT
C
WHEN CHECKED, BREAK ALL CORNERS
ANGLES TO BE: ±
DECIMAL DIMS TO BE: ±
WHEN CHECKED, REMOVE ALL BURRS
UNLESS OTHERWISE SPECIFIED:
INTERCONNECT DIAGRAM 6801M-20
ROTATING AUTOMATIC SWITCH
OPERATOR (STANDARD UNIT)
J8
J5
J10
J7
RELAY 1 RELAY 2
FUSE
TB1
TB2
+
+
-
-
BAT TEST BYPASS
GROUND
NEUTRAL
AC LINE
SHUNT
RESISTOR
BATTERY
ASSY
MOTOR
AC OUTLET
FACEPLATE GND
SPEED SENSOR
C/W EMI FILTER
SDA-11331-1
(+)
(-)
J12
J8 J9
J4 J6
TEMP
SENSOR
CIRCUIT
BREAKER
ADJ. TAP
HEATER
RESISTOR/
GND
PNL
PORT B
PORT A
COMM OPTION
SCADA PORTS
ENCLOSURE GND
SDA-10524
SDA-10645R1
SDA-10869-1
SDA-10870-1
SDA-10634
SD-11026
SDA-10866-1
PCB FP/PROC (FACEPLATE)
006-003051-01
J1
J2
J5
J9
J10
J7
J1 J2 J15 J14 J4
J6
J3
J11
RT1
007-000888-01
007-000780-01
007-000777-01
007-001099-02
1
2
(2 BELOW 1) (2 BELOW 1)
6
5
6
5
4
1
3
4
1
3
5
4
1
3
5
4
1
3
007-000773-03
007-000773-03
007-000773-01
007-000773-01
007-000773-02
(430-000024-03)
007-000779-01
007-000772-01
JUMPER (459-000041-00)
007-000774-01
007-000777-02
GRN
WHT
BLK
1
2
BRN
BLK
3
4
F1
A
B
B B
A
A
ON
OFF
BLK
BOTTOM
RED
VIO
ORG
TOP
BLK
BLU
YEL
TOP
BLK
BOTTOM
TR-20366
RED
BLK
J13
PCB PS/IO
006-001052-01
J16
SDA-11231
007-000778-01
SDA-11331-1
SDA-10763
SDA-11189
SDA-11188
007-000781-01
POWER
SUPPLY
RED/WHITE
BLK\WHITE
RED
GRN
BLK
G N L
P2
P1
SDA-10867-1
BLK
WHT
GRN
NOTES:
1. SEE SHEET 2 FOR WIRING TABLE.
2. AC OUTLET FOR 120V ONLY.
TXD (OUTPUT)
RTS (OUTPUT)
RXD (INPUT)
4
5
6 GND
SCADA PORTS J1/J2 (A/B)
POSITION
DEFINITION
+12 VDC
CTS (INPUT)
1
2
3
MANUAL HANDLE INTERLOCK
(PLUNGER SWITCH)
INHIBITS ELECTRICAL OPERATION
THROUGH CONTROL SOFTWARE
WHEN HANDLE REMOVED.
6801M-20 TORSIONAL 120/240 VAC