EasyManua.ls Logo

Santa Fe Compact 2 - User Manual

Santa Fe Compact 2
16 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
Rev 3/9/16
Installation & Operation Instructions
The Santa Fe Compact2 is designed for superior basement and crawl space
dehumidification. Tight spaces are no problem for the Santa Fe Compact2 dehumidifier.
Its compact size works perfect in low crawl spaces and small basements without
sacrificing power and performance. Designed to fit in a variety of small spaces, the
Compact2 provides multiple installation options for greater flexibility.
P/N: 4033600 Serial No.: Install Date:
Sold by:
www.Santa-Fe-Products.com 1.800.533.7533

Other manuals for Santa Fe Compact 2

Questions and Answers

  • B
    Brittney VargasJul 26, 2025
    Why is my Santa Fe Compact 2 Dehumidifier not removing enough water?
    • J
      Jeff PerryJul 27, 2025
      If your Santa Fe Dehumidifier isn't removing as much water as you expect, it could be due to several reasons. First, check the ambient air temperature and humidity levels, as a drop in either can reduce water removal. Ensure that your humidity meter and thermometer are properly calibrated. The unit may also be in a defrost cycle, so allow it to complete. Other potential causes include dirty air filters restricting airflow (clean or replace them), a defective defrost thermostat (test its functionality), a low refrigerant charge (check and replenish), air leaks (inspect for and seal them), a defective compressor (replace it), or restrictive ducting (inspect and modify).
  • L
    Linda LittleJul 31, 2025
    Why is my Santa Fe Compact 2 Dehumidifier evaporator frosted and dehumidifying poorly?
    • A
      Alisha WilsonJul 31, 2025
      If your Santa Fe Dehumidifier has low dehumidification capacity and the evaporator is continuously frosted, it could be due to a few reasons. The defrost thermostat might be loose or defective, so inspect, tighten, or replace it. Another potential cause is a low refrigerant charge, which requires checking and replenishing. Dirty air filters or restricted airflow can also lead to this issue, so clean or replace the filters. Finally, excessively restrictive ducting connected to the unit could be the problem; inspect and modify the ducting to improve airflow.
  • A
    Adam ChavezAug 5, 2025
    What to do if the Santa Fe Compact 2 fan and compressor are not running?
    • D
      Dylan GonzalezAug 6, 2025
      If neither the fan nor the compressor is running on your Santa Fe Dehumidifier, and dehumidification is needed, start by checking if the unit is properly plugged in and that the outlet has power. Also, verify that the humidity control isn't set too high. Inspect the internal and control wiring for any loose connections. If these steps don't resolve the issue, the compressor relay might be defective and require testing.
  • J
    Jesse BrownAug 10, 2025
    Why does my Santa Fe Compact 2 Dehumidifier compressor keep cycling on and off?
    • M
      michael76Aug 10, 2025
      If the compressor on your Santa Fe Dehumidifier cycles on and off while dehumidification is active, several factors could be responsible. Low ambient temperature or humidity might cause the unit to cycle through defrost mode; monitor these conditions. Other potential causes include a defective compressor overload (test it), a defective compressor (replace it), a defective defrost thermostat (test its functionality), dirty air filters restricting airflow (clean or replace them), or a defective fan or relay (test them).
  • J
    James WallaceAug 15, 2025
    What to do if Santa Fe Compact 2 compressor is not running but the fan is?
    • D
      Derek BarnettAug 16, 2025
      If the compressor isn't running on your Santa Fe Dehumidifier, but the fan is, and dehumidification is needed, it could be due to a defective compressor run capacitor (replace it). Check for loose connections in the compressor circuit. Other potential causes include a defective compressor overload (test it), a defective compressor (replace it), or an open defrost thermostat (inspect it).
  • J
    James BergerAug 21, 2025
    How to fix a Santa Fe Compact 2 fan that is not running?
    • J
      Jaclyn MullenAug 21, 2025
      If the fan on your Santa Fe Dehumidifier isn't running when dehumidification or fan operation is needed, check for loose connections in the fan circuit. Ensure that nothing is obstructing the fan impeller's rotation; remove any obstructions. If the connections are secure and there are no obstructions, the fan itself may be defective and need replacing, or the fan relay may be defective and require testing.

Summary

Safety Instructions

Intended Applications

Specifies the intended uses and environmental conditions for the Santa Fe Compact2 dehumidifier.

Registrations

Details compliance with unified standards UL 60335-2-40 and CSA standard C22.2.60335-2-40.

Specifications

Dehumidifier Set Up

Items Included in Box

Lists all components provided with the Santa Fe Compact2 dehumidifier.

Important Precautions

Highlights critical safety warnings and operational restrictions for the dehumidifier.

Location Considerations

Provides guidance on selecting an appropriate and safe location for the dehumidifier.

Installing Leveling Feet

Step-by-step instructions for attaching and adjusting the leveling feet for proper unit placement.

Ducting To Finished Areas (Optional)

Attaching Duct Collars

Instructions for connecting ductwork to the unit's air inlet and outlet.

Supply Air Outlet Configuration

Details on configuring the supply air outlet for horizontal or vertical airflow.

Recommended Installations

Illustrates two recommended ducting configurations for optimal performance in finished areas.

Drain Installation

Operation

Humidity Control Adjustment

Explains how to set the desired humidity level and control the unit's on/off cycles.

Defrost Cycle Function

Describes the automatic defrost feature to prevent frost build-up and protect the unit.

Fan Operation Modes

Details the two fan settings: continuous operation or operation only during dehumidification.

Air Filtration

Changing The Filter

Provides instructions for removing and replacing the pre-filter and MERV-8 filter.

MERV Rating Chart

Explains the MERV rating system and typical applications for different filter efficiencies.

Electrical Requirements

Wiring Schematic Diagram

Presents the electrical wiring diagram for the Santa Fe Compact2 dehumidifier.

Service

Replacement Parts List

Lists part numbers for common replacement components for the dehumidifier.

Refrigerant and Compressor Service

Covers refrigerant charging and compressor/capacitor replacement procedures.

Troubleshooting Guide

Provides common symptoms, possible reasons, and troubleshooting procedures for performance issues.

Warranty

Santa Fe Compact 2 Specifications

General IconGeneral
Operating Temperature Range49-95 °F
Voltage115V
Power Consumption240 W
Dehumidification Capacity10 liters per day
Tank CapacityN/A (Direct drain)
Noise Level55 dB

Related product manuals