6901-002029 <06>
7
Solid Concrete or Concrete Block
3-1 Mark the wall
[01]
[01]
[04]
[03]
[05]
[05]
3 Wall Mounting
For assistance in determining wall plate location, see Height Finder at
sanus.com.
Level the wall plate [01] and mark the hole locations.
CAUTION:
Avoid potential injuries or property damage!
Ù Mount the wall plate [01] directly onto the concrete surface.
Ù Minimum solid concrete thickness: 8 in.
Ù Minimum concrete block size: 8 x 8x 16 in.
002862.eps
002862.eps
75 mm
(3 in.)
[05]
3-2 Drill pilot holes
3-3 Insert anchors and lag bolts
CAUTION:
Avoid potential injuries or property damage! :
Ù Pilot holes MUST be drilled to a depth of 75 mm (3 in.) using a 10
mm (3/8 in.) diameter drill bit.
Ù Never drill into the mortar between blocks.
Insert lag bolt anchors [05]. Then insert lag bolts [04] using a drill and
the Allen Driver Bit [03].
CAUTION:
Avoid potential injuries or property damage!
Improper use could reduce the holding power of the lag bolt. To
avoid potential injuries or property damage:
Ù Be sure the anchors [05] seat flush with the concrete surface.
Ù Tighten the lag bolts [04] only until the they are pulled firmly
against the wall plate [01].
Ù DO NOT over-tighten the lag bolts [04].
10 mm
(3/8 in.)