2 - 4
2. Simple Settings Functions
2
Mini ECO-i System
Remote Controller Functions
0000 Not displayed
(The optimal setting for that model was set at the time of shipment.)
0001 150 hours
0002 2,500 hours
0003 5,000 hours
0004 10,000 hours
Filter sign ON time
(filter lifetime)
0005 Use the filter clogging sensor.
0001 Central control address 1
0002 Central control address 2
0003 Central control address 3
0064 Central control address 64
Central control address
0099 No central control address set (setting at time of shipment)
Compressor ON Compressor OFF
0000 MED 1 min., LO 3 min. LO
0001 MED LO
0002 LO LO
0004 MED 1 min., LO 3 min. MED
0005 MED MED
Fan speed when
heating thermostat is
OFF
0006 LO MED
0000 No shift
0001
Shifts intake temperature 1
Cdown.
0002
Shifts intake temperature 2
Cdown.
0003
Shifts intake temperature 3
Cdown.
0004
Shifts intake temperature 4
Cdown.
0005
Shifts intake temperature 5
Cdown.
Heating intake
temperature shift
0006
Shifts intake temperature 6
Cdown.
0000 Normal (Setting at time of shipment)
Cooling-only
0001 Cooling only
• In order to avoid water leakage and damage to the fan, do not set for humidifying when the thermostat is OFF
unless a vaporizing humidifier is used.
• Consider the device purpose and type when changing the settings. Incorrect settings may result in malfunction.
• Do not change any setting data that does not appear in this list.
List of Simple Setting Items
NOTE