(10) Dismounting
the
pressure sensor (Fig-14)
CD
Cut
off
the binding band and dismount the
connectors from
the
board.
® Loosen
the
mounting nut and dismount
the
pressure sensor.
(11) Dlsmountln.
the
front
panel (Fig.-15)
CD
Make sure that the chamber is not filled with water.
(%l
Tum
the
lever of
the
water
drain
to
·Open-.
@ Remove
the
8 front panel mounting screws.
® Dismount
the
front panel, paying attention to
the
switch cover.
(12) Dlsmountln.
the
lock
shaft
switch
(M Housing assembly) (Figs.-16 and
-17)
CD
Disconnect
the
connectors connected
to
the
switch.
(%)
Remove each 1
saew
which ftxes
the
switch.
;«CWhen
dismounting the switch,
pay
attention
not to
allow a tool
or
finger(s) to hit the
ectuator
of
the
micro-switch. Otherwise, the
(13) Dismounting
the
pressure gauge (Figs.-18 and -19)
CD
Remove
the
cap nut for piping of
the
pressure gauge.
(%)
Remove
the
saews
(3 pes.) which
fIX
the pressure
gauge.
Cap
nut
*
Pay
attention not
to
lose
the
O-ring (P5)
which is
inserted between
the
pressure gauge and
the
pipe. Also, do not tighten the cap
nut
too much
(14) Dismountin.
the
breaker
(Fig.-20)
CD
Remove
the
4 wires.
(%)
Remove the 2 breaker mounting screws.
-
47-
*·0
·
shows
the
saew
position.
s .......