-50-
Electrical Adjustment
Grp / No. Item Function Range Initial Note
155 CCA
0 CCA Disable 0:Enable,1:Disable 0 - 1 0
156 Color Matching - Measured Data
0 Measured Red - X
Adjust the Measured Data of Color Macthcing Function
0 - 1000 -
1 Measured Red - Y 0 - 1000 -
2 Measured Red - Luma 0 - 32767 -
10 Measured Green - X 0 - 1000 -
11 Measured Green - Y 0 - 1000 -
12 Measured Green - Luma 0 - 32767 -
20 Measured Blue - X 0 - 1000 -
21 Measured Blue - Y 0 - 1000 -
22 Measured Blue - Luma 0 - 32767 -
30 Measured Cyan - X 0 - 1000 -
31 Measured Cyan - Y 0 - 1000 -
32 Measured Cyan - Luma 0 - 32767 -
40 Measured Magenta - X 0 - 1000 -
41 Measured Magenta - Y 0 - 1000 -
42 Measured Magenta - Luma 0 - 32767 -
50 Measured Yellow - X 0 - 1000 -
51 Measured Yellow - Y 0 - 1000 -
52 Measured Yellow - Luma 0 - 32767 -
60 Measured Half White - X 0 - 1000 -
61 Measured Half White - Y 0 - 1000 -
62 Measured Half White - Luma 0 - 32767 -
70 Measured Full White - X 0 - 1000 -
71 Measured Full White - Y 0 - 1000 -
72 Measured Full White - Luma 0 - 32767 -
100 Measured Data Update Apply the adjusted data when the data set to 10. 0 - 10 -
160 VIDI
0 Brightness (Wheel)-Dynamic Brightness Wheel (Brightness) 0 - 10 4
1 Brightness (Wheel)-Not Dynamic Brightness Wheel (Color) 0 - 10 2
2 Color (Wheel)-Dynamic Brightness Wheel (Brightness) 0 - 10 5
3 Color (Wheel)-Not Dynamic Brightness Wheel (Color) 0 - 10 3
161 Lamp Sync
0 Brightness (Wheel)-x2 Mode 0 - 65535 178
1 Brightness (Wheel)-x3 Mode 0 - 65535 128
2 Color (Wheel)-x2 Mode 0 - 65535 429
3 Color (Wheel)-x3 Mode 0 - 65535 352
200 Option
0 Logo Display Prohibition 0:Menu 1:Forced 0 - 1 0
1 RS232C Baud rate 0: 19200bps 1: 9600bps 0 - 1 0
3 Shipping Set Shipping set when the value is set to 10 0 - 10 0
4 CABLE SW Long Cable 0: Disable 1: Enable 0 - 1 0
5 PW Debug Command Enable
0: Disable (Serial Command Enable)
1: Enable (PW Debug Mode)
0 - 1 0
6 Device Refresh Disable 0: Enable 1: Disable 0 - 1 0
11 HDCP EDID Data Setting 0: DVI EDID Data, 1: HDCP EDID Data 0 - 1 1
15 Lens Shift Centering Setting Execute Seting when the Value is changed to 10. 0 - 10 0
20
21 Lamp Warning Time (NORMAL) 1-16 4
22 Lamp Warning Time (ECO) 1-16 5
23 Lamp Warning Time (HIGH) 1-16 4
50 Lamp Replacement Display 1:On 0:Off 0 - 1 1
51 Filter Warning Display 1:On 0:Off 0 - 1 1
53 Filter Counter Reset Times Read only 0 - 255 0
54 Factory Default Executed Times Read only 0 - 255 0
56 Menu Position (X) X Offset 0 - 1024 0
57 Menu Position (Y) Y Offset 0 - 1024 0
58 Lamp Go Out Lamp goes out 0 - 1 0
59 LENS LOCK Warning Display 0: Enable 1: Disable 0 - 1 0
62 Color Wheel Warning 0: Enable 1: Disable 0 - 1 0
70 ADC Device Select for Analog PC 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
71 ADC Device Select for Component 0 = ISL51002, 1 = PW392 AFE 0 - 1 0
80 Destination Language Set at Shipping 0:English 1:Japanese 0 - 1 0
100 Disable Auto Picture Control 0 : Normal operation 1 : Auto Picture Control Off 0-1 Initial: 1 Shipping 0