5
English
G install the indoor unit more than 1 meter away from any antenna or power lines or connecting wires used for television,
radio, telephone, security system, or intercom. Electrical noise from any of these sources may affect operation.
G install in a sturdy manner to avoid increased operating noise.
Table 3
* If total tubing length becomes 45 to 80 m (max.), charge additional refrigerant (R410A) by 20 g/m.
No additional charge of compressor oil is necessary.
2-2. Connecting Indoor Units
Fig. 4b
UnionFlare
C
B
A
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
D
E
Outdoor unit Indoor unit
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KRV184EH)
(SAP-KRV186EH)
9.52
6.35
9.52
6.35
12.70
6.35
9.52
6.35
9.52
6.35
9.52
12.70
12.70
9.52
9.52
9.5212.70
( 12.70 9.52) Supplied reducer
UnionFlare
C
B
A
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
D
E
Outdoor unit Indoor unit
(SAP-KMRV74EH, KMRV94EH,KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH,KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
(SAP-KMRV74EH, KMRV94EH, KMRV124EH)
(SAP-KMRV76EH, KMRV96EH, KMRV126EH)
(SAP-KRV96EHDS, KRV126EHDS)
9.52
12.70
12.70
9.52
9.52
9.52
6.35
9.52
6.35
9.52
6.35
9.52
6.35
9.52
6.35
9.5212.70
( 12.70 9.52) Supplied reducer
(A)
(B)
Max. Allowable Max. Allowable Total Limit of Limit of Elevation Required Amount
Tubing Length Tubing Length Total Tubing Length Difference of Additional
Model per unit at shipment (L1+L2+L3+L4+L5) (H1, H2, H3, H4, H5) Refrigerant
(m) (L1+L2+L3+L4+L5) (m) (m) (g/m)
*
(m)
CMRV3656 30 45 (L1+L2+L3+L4+L5) 80 (L1+L2+L3+L4+L5) 15 20
Fig. 4a
unit: mm
Figures (A) – (H) show the different types of indoor unit connections, including the use of a reducer.
To select the required indoor unit to be connected, refer to the Combination Table that was included in the
outdoor unit package.
08-342 CMRV3656EH_OU EN 6/9/09 2:27 PM Page 5