EasyManua.ls Logo

Sanyo SAP-CMRV3656EH - 2-2. Major Component Specifications

Sanyo SAP-CMRV3656EH
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
P.C.Board
Circuit Fuse
Controls
Part No.
Microprocessor
400V 3.15A
CB-CMRV3656EH
Control P.C.B
-
250V 25A
POW-CMRV3656EH-B1
Noise Filter P.C.B
-
-
POW-CMRV3656EH-C1
H.I.C.Board
1 ... D490
Propeller
DC Motor
SIC-71FW-D881-1 ... 1
8
-
81
750 / 700
Internal Controller
Yes
Yes
-
-
Aluminum Plate Fin / Copper Tube
2
1.2
0.792
Fan
Q'ty ... Dia.
Type
mm
Fan Motor
Nominal Output
Coil Resistance
Rough Measure RPM (Cool:Hi / Heat:Hi)
Type
Model ... Q'ty
No. of Poles
Safety Device
Type
Over- Current Protection
Over- Heat Protection
(Ambient Temp. 20 °C)
Run Capacitor Micro F
VAC
W
Ohm
Face Area
Coil
Rows
Fin Pitch
Heat Exchanger Coil
m
2
mm
DATA SUBJECT TO CHANGE WITHOUT NOTICE.
2-2. Major Component Specifications
2-2-1. Outdoor Unit
Outdoor Unit SAP-CMRV3656EH
C-9RVN273H0H / 2,700W
DC Twin Rotary (Hermetic)
Compressor
Compressor Model / Nominal Output
Type
FV68S ... 1,400Compressor Oil ... Amount CC
T - R : 0.169Coil Resistance (Ambient Temp. 25 °C) Ohm
T - S : 0.169
R - S : 0.169
Safety Device
YesCT (Peak current cut-off control)
YesCompressor Discharge Temp. Control
Yes
Operation cut-off control in abnormal ambient Temp.
CS-7LOverload Relay
Open : 115 °C, Close : 100 °C
Model
Operation Temp.
-Run Capacitor
-
Micro F
VAC
230V 25WCrankcase Heater
Acrylic baked-on enamel finishExternal Finish
8

Table of Contents

Related product manuals