Sanyo SAP-CMRV3656EH - Wiring Instructions for the Outdoor Unit

Sanyo SAP-CMRV3656EH
70 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
17
English
123 123
123 123
LN
123
ABC
DE
1
2
3
1
2
3
1
2
3
1
2
3
1
2
3
D
A
B
C
E
Indoor unit E
Indoor unit B
Indoor unit A
Indoor unit C
A is the indoor unit with
refrigerant tubing that is
connected to service valve
A (bottom) of the outdoor unit.
B is the indoor unit with refrigerant
tubing that is connected to
service valve B (second from
the bottom) of the outdoor unit.
Indoor unit D
D is the indoor unit with refrigerant
tubing that is connected to
service valve D (fourth from
the bottom) of the outdoor unit.
C is the indoor unit with refrigerant
tubing that is connected to
service valve C (third from the
bottom) of the outdoor unit.
connected to service valve
E (top) of the outdoor unit.
refrigerant tubing that is
E is the indoor unit with
Be sure to perform grounding.
Attach a ground wire to either the
outdoor unit or indoor unit.
If there is a grounding terminal
inside the room, use the grounding
screw inside the indoor unit.
Be sure to apply the provided labels to both
ends of the inter-unit cables to prevent mis-
wiring. The units will not function if the wiring
connections are incorrect.
Inter-unit cables
Terminal board
Label E
1.0 mm
2
(not provided)
Inter-unit cables
Label D
1.0 mm
2
(not provided)
Terminal board
Terminal board
Label C
Inter-unit cables
1.0 mm
2
(not provided)
Inter-unit cables
Terminal board
Label B
1.0 mm
2
(not provided)
Inter-unit cables
Terminal board
1.0 mm
2
(not provided)
Label A
Power:
Single-phase,
220/240VAC 50Hz
Leakage breaker/fuse link
(not provided)
Ground
Power cable (not provided)
(3.5 mm
2
: Less than 26 m)
Outdoor unit
Terminal board
5-5. Wiring Instructions for the Outdoor Unit
G Be sure to correctly align inter-unit cables A, B, C, D and E.
G Use a dedicated air conditioner circuit for power.
G To make connections to the outdoor unit, remove the inspection panel and tubing panel.
G Do not bring the inter-unit cables or power cable into contact with tubing or service valves.
G Use outdoor unit cable fasteners and fasten the inter-unit cables at the location where the cables are double-
sheathed.
G Arrange the wiring so that the inter-unit cables are contained in the inspection panel and tubing panel, as shown
in Fig. 31.
CAUTION
Fig. 31
08-342 CMRV3656EH_OU EN 6/9/09 2:27 PM Page 17