TECHNICAL & SERVICE MANUAL
SAP-K77RAX + SAP-C77RAX
SAP-K97RAX + SAP-C97RAX
SAP-K127RAX + SAP-C127RAX
SPLIT SYSTEM AIR CONDITIONER
Indoor Model No.
SAP-K77RAX
SAP-K97RAX
SAP-K127RAX
Indoor Unit
Product Code No.
1 852 350 01
1 852 350 02
1 852 350 03
FILE NO.
Outdoor Model No.
SAP-C77RAX
SAP-C97RAX
SAP-C127RAX
Product Code No.
1 852 350 04
1 852 350 05
1 852 350 06
Outdoor Unit
SAP-K77RAX
SAP-K97RAX
SAP-K127RAX
SAP-C77RAX
SAP-C97RAX
SAP-C127RAX
REFERENCE NO. SM700754
Destination: Russia (50Hz)

Table of Contents

Questions and Answers:

Sanyo SAP-K127RAX Specifications

General IconGeneral
BrandSanyo
ModelSAP-K127RAX
CategoryAir Conditioner
LanguageEnglish

Summary

Important Safety and Installation Guidelines

Pre-Installation Safety and Handling

Key safety requirements, transport precautions, and installation site considerations for optimal unit performance.

Servicing and Other Considerations

Procedures for servicing and important notes regarding refrigerant and ventilation.

Operating Range Specifications

Technical Specifications

Unit Specifications

Detailed technical specifications for indoor and outdoor units, including performance and electrical ratings.

Major Component Specifications

Technical details for key internal components like PCB, motors, and heat exchangers for each unit model.

Other Component Specifications

Specifications for additional components such as thermistors and power relays used in the system.

Dimensional Data

Refrigerant System Information

Refrigerant Flow Diagram

Illustrates the path of refrigerant through the system components during the cooling cycle.

Refrigerant Tubing Insulation

Emphasizes the importance of insulating refrigerant tubing to prevent heat loss and condensation.

Performance Data

Cooling Performance Charts

Graphs showing cooling characteristics, including operating current and pressure vs. outdoor temperature.

Air Throw Distance Charts

Charts illustrating air throw distance based on flap angle and air velocity for cooling mode.

Cooling Capacity Tables

Tables detailing cooling capacity (TC, SHC) under various indoor and outdoor temperature conditions.

Electrical Data

Electrical Characteristics

Lists electrical ratings, running amperes, and power input for different operating conditions.

Electric Wiring Diagrams

Provides schematic diagrams for wiring the indoor and outdoor units, including terminal connections.

Installation Instructions

Installation Site Selection

Guidelines for choosing appropriate locations for indoor and outdoor units to ensure optimal performance and safety.

Recommended Wire Length and Diameter

Recommendations for power supply wiring length and cross-sectional area based on model and distance.

Remote Control Unit Installation Position

Advice on optimal placement of the remote control for correct operation and avoiding interference.

Test Run Procedure

Step-by-step procedure for conducting a test run of the air conditioner's cooling mode.

Grille Removal and Installation

Instructions for safely removing and reinstalling the indoor unit's front grille and anti-mold filter.

Remote Control Address Setting

Procedure to change the remote control address for preventing interference between multiple units.

Air Conditioner Functions

Room Temperature Control

Explanation of how the unit maintains room temperature by cycling the compressor.

Dry Operation (Dehumidification)

Details on the dehumidification function, how it works, and its operating zones.

Freeze Prevention

Description of the freeze prevention mechanism for the indoor heat exchanger coil.

Automatic Fan Speed Adjustment

How the unit automatically adjusts indoor fan speed based on temperature differences.

Troubleshooting Guide

Initial Checks and Power Issues

Essential checks before diagnosing issues, including power supply and wiring verification.

Unit Not Operating

Steps for diagnosing and resolving issues when the air conditioner does not operate, including circuit breaker trips.

Partial Operation Failures

Diagnosing issues where only specific components fail to operate, like fans or compressor.

Performance Abnormalities

Troubleshooting steps for common performance issues like poor cooling or excessive cooling.

Electrical Component Checks

Insulation Resistance Measurement

Procedure for measuring insulation resistance of power cords, units, and electrical parts.

Fuse and Capacitor Checks

Methods for checking fuse continuity and testing motor capacitor functionality.