SETTINGS
Line phase adjustment
When using a camera switcher to connect 2 cameras or more to
one monitor, there may be a vertical roll of the images when
switched. In such a case, set as described below.
1 Set the SYNC switch to the L-L position.
2 Switch the display on the monitor from camera 1 to camera 2.
Adjust the LINE PHASE volume on camera 2 until the vertical
roll of the image stops.
If more than two cameras are used, please repeat this
procedure for all the cameras.
CAUTION:
If the vertical roll cannot be corrected by setting the LINE PHASE
volume on camera 2, try setting the LINE PHASE volume on
camera 1. If it still cannot be corrected, please check that the
polarity of the power cords of all connected devices is correct.
AGC setting
AGC (Automatic gain control) can be turned ON or OFF.
ON: Auto gain control
OFF: Fixed gain
E. S.
L
E
V
E
L
DC
VIDEO
A. I.
LENS
LH
VR301
ON
123
OFF
ON
L-L
INT
AGCSYNC
ON
OFF
BLC EI
[VCB-3100P]
ON
OFF
ON
E. S.
BLC
L
E
V
E
L
DC
VIDEO
A. I.
LENS
LH
VR301
ON
123
EI
OFF
ON
SYNC
L-L
INT
VR302
AGC
[VCB-3170P]
L-L
INT
OFF
ON
AGC
L73M5, N5/XE GB 1996, 10, 31
8 English