EasyManua.ls Logo

Sanyo VM-EX280P - REC AFM Recording Current Check; REC ATF Recording Current Check

Sanyo VM-EX280P
87 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
12. REC AFM Recording Current Check
[Connection]
13. REC ATF Recording Current Check
[Connection]
J1OO5
[Adjustment / Check]
WeaeuringPoint I
Meaeuring Equipment
Condition
1
TP133 (CH1)
Oscilloscope
Record
TP143 (GND)
MP type tape
I
I
Input Signal / Alignment Tape
I
Color bar (Audio input: No signal)
I
ADJ. Location
ADJ. / Check Value
160 i 15 mVp-p
Preparation:
POWER switch: “CAMERA
Stand-by switch: “STANDBY”
Short pin @, pin @ and pin @ of J1OO5.
Adjusting / Checking method:
[ For VM-EX220P ]
1, Confirm that the oscillation voltage is 160 t 15 mVp-p.
[ For VM-EX280P/370P ]
1. Confirm that the oscillation voitage is 330 t 15 mVp-p.
L
160 t 15 mVp-p
T
T
330 f 15 mVp-p
1
J1OO5
TP134
TP143
!3
o
CH1
o
EXT
0CH2
[Adjustment / Check]
Measuring Point I
Meaeuring Equipment
Condition
TP134 (CH1)
TP143 (GND)
~
Color bar
ADJ. Location
ADJ. I Check Value
125 f 25 mVp-p
Preparation:
POWER switch: “CAMERA
Stand-by switch: “STANDBY
Short pin @, pin @ and pin @ of J1OO5.
Adjusting / Checking method:
1.
Confirm that the oscillation voltage is 125 t 25 mVp-p.
14--lO,usec+
T
125 f 25 mVp-p
--L
5-20

Table of Contents