Do you have a question about the Sartorius CPA 34001S and is the answer not in the manual?
Readability | 0.1 mg |
---|---|
Calibration | External |
Display | LCD |
Material | Stainless Steel |
Interface | RS-232 |
Maximum Capacity | 34 kg |
Pan Size | Ø 85 mm |
Power Supply | AC Adapter or Battery |
Weighing Pan Size | Ø 85 mm |
General safety advice for using the balance and handling potential hazards.
Safety measures to follow during the installation process of the balance.
Guidelines for storing and shipping the balance to prevent damage.
Procedures for unpacking the balance and checking for any external damage.
Choosing a suitable location and conditioning the balance for optimal performance.
Information about the control seal for balances verified for legal metrology in the EU.
Steps for setting up the CPA2P model balance with its components.
Steps for setting up the CPA2P-F model balance with its components.
Instructions for installing the draft shield on analytical balances.
Procedure for connecting the CPA26P and CPA225D models to the electronics box.
Steps for placing and securing the 3-sided draft shield on the balance.
Procedure for placing components on scales with rectangular pans up to 10 kg.
Procedure for placing the weighing pan on scales with rectangular pans over 10 kg.
Instructions for connecting the balance to the AC power supply and safety precautions.
Guidance on selecting and connecting country-specific power cords for the AC adapter.
Important safety information regarding the plug-in AC adapter and grounding.
Procedure for connecting peripheral devices like printers or PCs to the interface port.
Information on the necessary warmup time for the balance to deliver exact results.
Instructions for securing the balance using an antitheft locking device.
Steps to level balances with a weighing capacity up to 10 kg using front feet.
Procedure to level balances with a weighing capacity over 10 kg using leveling feet.
Description of the balance display and all operating elements and their functions.
Explanation of the basic weighing function and its features.
Tips for steady and uninterrupted weighing techniques with microbalances.
Steps for preparing and performing basic weighing, including tare function.
Specific instructions for filter weighing using the CPA2P-F model.
Procedure for setting up below-balance weighing for analytical and precision balances.
Steps to perform below-balance weighing with the CPA2P microbalance.
Explanation of calibration and adjustment purpose, features, and conditions.
Requirements for internal calibration/adjustment for legal measuring instruments.
Information on external calibration for verified balances of accuracy class II.
Detailed steps for performing internal calibration and automatic adjustment.
Configuring the sequence of calibration and adjustment via setup menu.
Setting up automatic calibration and adjustment (isoCAL) via menu codes.
Restrictions on isoCAL function for balances used in legal metrology.
Setting up external calibration mode and performing the calibration steps.
Adapting the balance to individual requirements via setup menu options.
How to print current menu settings at different menu levels.
Detailed steps for setting balance parameters using menu codes and adapting to conditions.
Overview of weighing parameters including filter, stability, tare, and unit settings.
Configuration of display accuracy, CAL key functions, and calibration/adjustment sequences.
Selecting application programs like Weighing, Counting, and Percent Weighing.
Configuration of weight units, decimal places, and animal weighing parameters.
Setting parameters for the data interface: baud rate, parity, and stop bits.
Configuring handshake modes and communication modes for data transfer.
Configuring print settings for manual/automatic output and tare balance printing.
Settings for printing application parameters, line format, and ISO/GLP printouts.
Configuration of extra functions like acoustic signals, keypad lock, and power-on modes.
Settings for reference balance in counting and resetting menu to factory settings.
Configuring measurement environment parameters for ISO/GLP records and display brightness.
Step-by-step guide for setting the time, date, and adjusting display brightness.
Overview of function keys (F, CF) used for starting, toggling, and ending application programs.
Information on using application programs with balances verified for legal measuring instruments.
Weighing components to a defined total, storing, and clearing component data.
Setting parameters for net-total formulation and automatic printout.
Example printout format for net-total formulation data, showing components and totals.
Step-by-step guide for using the net-total formulation program for counting parts.
Determining the number of parts by weighing a reference sample quantity.
Using function keys (F, CF) and setting the reference sample quantity.
Activating automatic reference sample updating for optimized counting accuracy.
Using a reference balance for higher precision in counting large amounts of parts.
Setting parameters for the counting program, including storage and reference balance.
Example printout format for the counting program, showing reference quantity and calculated quantity.
Step-by-step guide for counting parts of equal weight using the counting program.
Obtaining weight readouts in percent relative to a reference weight.
Using function keys (F, CF) and setting the reference percentage.
Setting parameters for the weighing in percent program, including storage and decimal places.
Example printout format for weighing in percent, showing reference percentage and calculated percentage.
Step-by-step guide for determining residual weight in percent using the program.
Determining weights of unstable samples by averaging multiple weighing operations.
Using function keys (F, CF) and changing the number of subweighing operations.
Setting parameters for the animal weighing program, including animal activity and start mode.
Example printout format for animal weighing, showing subweighing operations and calculated average.
Step-by-step guide for animal weighing with automatic start of subweighing operations.
Switching the display of weight values between two different weight units.
Using the function key (F) to toggle between weight unit 1 and weight unit 2.
Generating printouts with weights, measured values, and identification codes.
Configuring manual/automatic printout, line format, and ISO/GLP printout settings.
Examples of printout formats, showing how data is displayed with and without ID codes.
Generating printouts of initialization values and automatic weight readout printing.
Parameters included in GLP headers and footers for weighing series.
Configuring menu codes for ISO/GLP-compliant records and line format.
Connecting the balance to a computer or peripheral device via the serial interface port.
Default settings for transmission rate, parity, stop bits, and handshake.
Description of data output format with 16 characters, including normal operation and special codes.
Description of data output format with 22 characters, including ID codes and unit symbols.
Formats for sending control commands to the balance, including escape sequences.
Ensuring error-free data communication by matching parameters between balance and connected device.
Configuring handshake modes and communication modes for data transfer.
Controlling software handshake using XON/XOFF signals for device communication.
Using print commands and automatic data output modes for the interface port.
Details of the 25-contact D-Submini female interface connector.
Specifications for male connectors and warnings about using pre-wired RS-232 cables.
Detailed breakdown of pin assignments for the interface connector, including signal ground and data lines.
Diagram illustrating the cabling for connecting a computer or peripheral device via RS-232C/V24.
Common display error codes, their causes, and suggested solutions for troubleshooting.
Troubleshooting for constant weight readout changes and incorrect weight readings.
Steps to prepare the CPA2P model for safe transport, including removing parts.
Steps to prepare the CPA2P-F model for safe transport, including removing filter pan.
Information on Sartorius service contracts, repair procedures, and cautions.
Instructions for cleaning the balance exterior, weighing chamber, and stainless steel parts.
Detailed steps for cleaning the weighing chamber and removable draft shield components.
Procedures for safety inspection and recommended checks for the power supply.
Guidelines for proper disposal of packaging, equipment, and batteries according to EU legislation.
Technical specifications for CPA2P and CPA2P-F models, including weighing range, readability, and dimensions.
Technical specifications for various CPA and GCA models, covering capacity, readability, and dimensions.
Technical specifications for GCA models, detailing weighing capacity, readability, and operating conditions.
Technical specifications for CPA models, including capacity, readability, and dimensions.
Technical specifications for CPA and GPA models, covering capacity, response time, and interface.
Technical specifications for various CPA models, including weighing capacity, temperature range, and dimensions.
Technical specifications for CPA models, detailing accuracy class, capacity, and operating temperature.
Technical specifications for CPA models, including accuracy class, capacity, and temperature range.
Technical specifications for CPA and GC models, covering capacity, readability, and operating temperature.
Technical specifications for CPA and GPA models, including capacity, response time, and interface.
Technical specifications for CPA models, covering capacity, temperature range, and dimensions.
Technical specifications for CPA models, including capacity, scale interval, and temperature range.
Description and order numbers for optional data printers and reflective remote displays.
Information on external rechargeable battery packs for continuous operation.
Options for carrying cases designed for different balance models.
Software for data transfer and accessories like density kits, antistatic pans, and calibration weights.
Industrial AC adapters and analytical draft shield chambers for specific balance models.
Optional draft shield covers and data cables for PC connection.
Universal remote control switches, foot switches, and T-connectors for balance operation.
Accessories for below-balance weighing and weighing bowls of various volumes.
Dust covers available for display units of various CPA and GPA models.
Regulation of non-automatic weighing instruments for legal metrology by Council Directive 90/384/EEC.
Information on Sartorius's EC verification services for legal metrological verification.
Details on the validity of verification and national regulations for subsequent verifications.
Declaration stating compliance with European Directives for electromagnetic compatibility and electrical safety.
Declaration of conformity for weighing instruments, listing models, accuracy classes, and EC type-approval numbers.
Details of the EC type-approval certificate, including issuing body and validity.
Explanation of plates and markings on BC BL and BD BL balance types.
Explanation of plates and markings on the BF BL 500 balance type.
Legend explaining the meaning of various symbols (K, M, S, MD, T) found on balance plates.
Illustration of a plate showing the model designation and CE marking.
Illustration of a descriptive plate for a verified weighing instrument, including isoCAL information.
Contact details for Sartorius AG and copyright information regarding the manual's content.