Operating Instructions
Sartorius Cubis Series
Electronic Semimicro, Micro, Precision and Analytical Balances
MSE Models
1000025315
Question and Answer IconNeed help?

Do you have a question about the Sartorius MSE224S and is the answer not in the manual?

Sartorius MSE224S Specifications

General IconGeneral
Maximum Capacity220 g
Readability0.1 mg
Repeatability0.1 mg
Linearity± 0.2 mg
Pan SizeØ 85 mm
DisplayLCD
CalibrationInternal
InterfaceRS232
Operating Temperature10 °C to 30 °C
Operating Humidity15% to 80% (non-condensing)
Stabilization time (typical)2 seconds

Summary

Safety Instructions

Danger of Explosion!

Warning about operating the equipment in explosive environments.

Danger of Electrical Shock!

Warning about electrical hazards and proper usage.

Hazards at the Place of Installation and During Operation

Identifies hazards related to installation and operational use.

Intended Use

Getting Started

Connecting the Weigh Cell to the Electronics Module/Evaluation Unit

Instructions for connecting the weigh cell to the electronics module.

Leveling the Balance, Setting the Level Indicator

Ensuring the balance is level for accurate weighing.

Preparing Below-Cell Weighing

Setup instructions for performing weighing below the balance.

Installation Instructions

Guidance on selecting a suitable location and setup conditions.

Power Connection

Instructions for connecting the balance to the power supply.

Leveling the Balance Manually

Step-by-step guide for manual balance leveling.

Level the balance.

Ensuring the balance is level for accurate measurements.

Operation

Basic Weighing Function

How to perform a standard weighing operation.

Level the Balance (Q-Level)

Procedure for leveling the balance using the inclination sensor.

Calibration and Adjustment

Procedures for calibrating and adjusting the balance for accuracy.

isoCAL*: automatic calibration and adjustment

Details on the automatic calibration and adjustment feature.

Internal Calibration/Adjustment

Detailed procedure for internal calibration and adjustment.

Quick Guide: First Weighing

A simplified step-by-step guide for initial weighing.

Internal Calibration

Steps for performing internal balance calibration.

External Calibration

Procedure for performing external calibration with weights.

Configuration (Operating Menu)

Menu Structure (Overview)

Hierarchical overview of the balance's configuration menu.

Parameter Settings: Overview

A detailed overview of available parameter settings.

Application programs

Configuration settings for various application programs.

Application Programs

Density Determination

Application for determining the density of solid materials.

Counting

Application for determining the number of parts with equal weight.

Example: Counting parts of equal weight

Step-by-step guide for using the Counting application.

Weighing in Percent

Application to obtain weight readouts as a percentage of a reference.

Example: Determining residual weight in percent

Step-by-step guide for residual weight calculation.

Calculation

Application for calculating weights using multipliers or divisors.

Example:

Step-by-step guide for calculating weight per unit area.

Averaging (animal weighing)

Application for determining weights of unstable samples via averaging.

Example: Automatic weighing of animals with 20 subweighing operations

Step-by-step guide for automatic animal weighing.

Net-total Formulation

Application for weighing components to a defined total weight.

Example: Counting parts into a container

Step-by-step guide for formulation (counting parts into container).

Totalizing

Application to sum successive weight values exceeding balance capacity.

Example: Totalizing weight values

Step-by-step guide for totalizing weight values.

Mass Unit Conversion

Application to change displayed weight units.

Example: Determining the density of a solid sample.

Step-by-step guide for density determination.

ISO/GLP-compliant Printout

Data Interfaces

USB Port (PC)

Connecting the balance to a PC via USB.

Pin Assignment Chart

Diagram showing pin assignments for the 25-pin interface.

Data Output

Parameters for configuring data output activation.

Data Input

Sending control commands to the balance.

Overview of SBI Commands

List and description of available SBI commands.

Bluetooth® Interface (optional)

Information on the optional Bluetooth interface.

Connecting the Balance via USB

Step-by-step guide to connect the balance using a USB port.

Error message

Explains error messages and their corresponding codes.

Installing Software Drivers

Instructions for installing necessary software drivers.

Error Messages

Care and Maintenance

Cleaning the Weighing Chamber of Balances with a Readability of ≤1µg

Cleaning instructions for the weighing chamber of high-precision balances.

Safety Inspection

Checks to ensure the balance is safe to operate.

Cleaning the Weighing Pan

Instructions for cleaning the weighing pan.

Cleaning the Balance

General instructions and precautions for cleaning the balance.

Technical Specifications

Model-specific Data

Specifications for verified precision balance models.

Balance Dimensions

Accessories (Options)

Plates and Markings