EasyManua.ls Logo

Sartorius MSE10202S User Manual

Sartorius MSE10202S
121 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Page #1 background imageLoading...
Page #1 background image
Operating Instructions
Sartorius Cubis Series
Electronic Semimicro, Micro, Precision and Analytical Balances
MSE Models
1000025315
Question and Answer IconNeed help?

Do you have a question about the Sartorius MSE10202S and is the answer not in the manual?

Sartorius MSE10202S Specifications

General IconGeneral
Maximum Capacity10200 g
Capacity10200 g
Readability0.01 g
Pan Size386 x 246 mm
Dimensions490 x 300 x 98 mm
Stabilization Time (typical)1.5 s
CalibrationInternal
Repeatability (Std. Dev.)0.01 g
InterfaceRS-232
Operating Temperature10-30 °C
Linearity±0.02 g

Summary

Safety Instructions

Danger of Explosion!

Warns about using the equipment in hazardous areas with explosive materials.

Danger of Electrical Shock!

Details electrical safety precautions, including adapter and cord checks.

Safety Instructions - Continued

Hazards at the Place of Installation and During Operation

Covers hazards like static electricity, glass breakage, hazardous materials, and magnetic fields.

Getting Started

Unpacking the Equipment

Provides step-by-step instructions for safely unpacking the balance.

Installation Instructions

Details how to select a proper setup location, avoiding negative environmental influences.

Getting Started - Continued

Balance with Draft Shield

Instructions for removing the balance with a draft shield from its packaging.

Balance with No Draft Shield

Instructions for removing the balance without a draft shield from its packaging.

Getting Started - Assembly

Assembly

Step-by-step guide for installing the analytical draft shield and assembling the balance.

Getting Started - Milligram Balances

Installing the Draft Shield Labeled DE for Milligram Balances

Instructions for assembling the draft shield for milligram balances.

Assembly of Milligram Balances without Glass Draft Shield (DR Option)

Guide for assembling milligram balances without a glass draft shield.

Getting Started - Precision Balances

Assembly for Precision Balances without Draft Shield with a Weighing Range up to 15 kg

Instructions for assembling precision balances without a draft shield up to 15 kg.

Getting Started - Higher Capacity Balances

Models with a Weighing Range from 20 kg Upwards

Specific instructions for placing the weighing pan on models with a weighing range of 20 kg and above.

Getting Started - Component Connection

Connecting the Weigh Cell to the Electronics Module/Evaluation Unit

Describes how to connect the weigh cell to the electronics module using the provided cable.

Getting Started - Setup Adjustments

Power Connection

Details how to connect the balance to the power supply, including voltage and plug checks.

Getting Started - Transport and Safety

Getting Started - Device Connection

Safety Precautions

Important safety notes regarding the AC adapter's grounding and data port connections.

Getting Started - Leveling

Getting Started - Accessories

Getting Started - Unit Configuration

Getting Started - Draft Shield Removal

Getting Started - Unit Replacement

Level the balance.

Reiteration of the importance of leveling and how to do it with the inclination sensor.

Getting Started - Unit Removal

Getting Started - Semi-microbalance Setup

Getting Started - Below-Cell Weighing

Preparing Below-Cell Weighing

Instructions on preparing the balance for weighing below the weighing cell.

Getting Started - High Precision Weighing

Getting Started - Draft Shield Cable

Operation - Control Panel

Overview of Display and Control Panel

Detailed description of the balance's display and control panel elements and their functions.

Operation - Basic Weighing

Basic Weighing Function

Explains the basic weighing procedure, including taring and printing.

Quick Guide: First Weighing

A simplified step-by-step guide for performing the first weighing operation.

Operation - Leveling and Ionizer

Level the Balance (Q-Level)

Explains the importance of leveling and how to use the level indicator for accurate results.

Leveling the Balance Manually

Step-by-step guide for manually leveling the balance using the leveling feet.

Operation - Draft Shield Control

Operation - Calibration

Calibration and Adjustment

Explains the purpose and features of calibration and adjustment procedures.

Internal Calibration

Describes how to perform internal calibration using the balance's built-in motorized weight.

Operation - Automatic Calibration

isoCAL*: automatic calibration and adjustment

Details the automatic calibration and adjustment function, including triggering conditions and configuration.

Operation - Calibration Procedures

Internal Calibration/Adjustment

Provides detailed steps and key functions for performing internal calibration.

External Calibration

Explains how to perform external calibration using a standard weight.

Configuration (Operating Menu)

Configuration - Menu Overview

Menu Structure (Overview)

A detailed overview of the balance's menu structure, organized by levels and parameters.

Configuration - Parameter Settings

Parameter Settings: Overview

A comprehensive overview of parameter settings, indicating factory and user-defined options.

Configuration - Device and Interface Settings

Configuration - PC Connectivity

Configuration - Application Programs Overview

Application programs

Overview of available application programs like Weighing, Counting, and Calculation.

Configuration - Input Settings

Configuration - System Information

Configuration - Time and ID Setup

Application Programs - Density

Density Determination

Explains how to determine the density of solid materials using the buoyancy method.

Application Programs - Density Data

Application Programs - Density Example

Application Programs - Counting

Counting

Explains how to count parts with approximately equal weight.

Application Programs - Counting Example

Application Programs - Weighing in Percent

Weighing in Percent

How to obtain weight readouts in percent relative to a reference weight.

Application Programs - Percent Example

Application Programs - Calculation

Calculation

Explains how to calculate weight values using a multiplier or divisor.

Application Programs - Calculation Example

Application Programs - Averaging

Averaging (animal weighing)

How to determine weights of unstable samples by averaging multiple measurements.

Application Programs - Averaging Example

Application Programs - Net-total Formulation

Net-total Formulation

How to weigh different components to a defined total weight.

Application Programs - Formulation Example

Application Programs - Totalizing

Totalizing

How to add mutually independent weight values to a total exceeding balance capacity.

Application Programs - Totalizing Example

Application Programs - Unit Conversion

Mass Unit Conversion

How to change the displayed weight unit to one of four application weight units.

Data Interfaces - Overview

Data Interfaces - USB Connectivity

USB Port (PC)

Information on connecting the balance to a PC via USB, including system requirements and software drivers.

Connecting the Balance via USB

Step-by-step instructions for connecting the balance to a computer using a USB cable.

Installing Software Drivers

Guide for installing the necessary software drivers for USB connectivity.

Data Interfaces - USB Management

Data Interfaces - Pin Assignments

Data Interfaces - Cabling

Data Interfaces - Output

Data Output

How to define data output parameters for print commands or automatic synchronization.

Data Interfaces - Output Details

Data Interfaces - Output Formatting

Data Interfaces - Input Commands

Data Input

How the computer can send control commands to the balance using SBI commands.

Data Interfaces - SBI Commands

Overview of SBI Commands

Lists SBI commands and their corresponding actions/functions for controlling the balance.

Data Interfaces - Optional Interfaces

Data Interfaces - Bluetooth

Bluetooth® Interface (optional)

Instructions for configuring and establishing a connection with a Bluetooth® printer.

Error Messages

Care and Maintenance - General

Cleaning the Balance

Detailed instructions for cleaning the balance, including safety precautions and IP protection considerations.

Care and Maintenance - Cleaning Components

Care and Maintenance - High Precision Cleaning

Care and Maintenance - Safety Inspection

Safety Inspection

Guidelines for inspecting the balance and AC adapter for safe operation.

Care and Maintenance - Transport Packing

Care and Maintenance - Draft Shield Packing

Care and Maintenance - Small Pan Packing

Care and Maintenance - Small Draft Shield Packing

Care and Maintenance - Panel Packing

Care and Maintenance - Final Packing

Technical Specifications - Verified Precision Balances Continued 3

Model-specific Data

Lists verified model data for precision balances with EC type approval.

Related product manuals