EasyManua.ls Logo

SATA Vision 2000 - Page 34

Default Icon
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
143
EN
Operating Instructions SATA vision 2000
Operating Instructions SATA vision 2000
chapter 8.2).
Close the carrier frame.
Check the eld of vision.
Close the hook-and-loop tape on the head/breast cloth.
9.3. Checking the service life
Notice!
Before every use, check the service life of the activated charcoal ab-
sorber / activated charcoal lter. If the service life (max. 3 months) is
exceeded, it must be replaced.
Check the service life of the activated charcoal absorber / activated
charcoal lter and replace, if necessary (variant 1, see chapter 10.1,
variants 2 and 3, see operating instructions for SATA lter 464).
9.4. Make the breathing protection apparatus ready to use
Warning!
Drop in air flow
When using a paint spray gun at the same time with variant 1 and var-
iant 3 with the SATA gun compressed air hose 1,2 m (# 13870), the air
volumetric ow rate may drop (see chapter 4).
Set the input pressure with the trigger guard of the paint spray gun
fully pressed (see chapter 7).
Holding the trigger guard pressed, increase the working overpressure
at the lter unit until the acoustic warning signal no longer sounds (this
can vary, depending on spray gun, hose length, etc.).
Notice!
The belt unit must be connected to the compressed air supply system.
Variant 1 [1]
Connect gun compressed air hose [1-5] to the air connection of the
paint spray gun.
Connect gun compressed air hose to air connection [1-6].
Take the air hose through the belt unit.
Connect air hose [1-3] to the air connection for breathing air [1-12].
Option
Connect top air humidier [1-4] to air hose [1-3].