e) that the conditions for
ventilation are guaranteed
for models C (no less than
100 square cm of free light)
and normal maintenance should
the boiler be enclosed inside or
between furniture;
After each reopening of
the gas tap, wait ten or twenty
seconds before turning the
appliance on.
in the plant.
d) that the supply of
combustion air and the
evacuation of fumes take place
in the manner established
by current legislation (UNI
CIG Standards 7129, 7131)
39
Due to its danger, it is
forbidden to
operate extractors, fireplaces
and the like in the same room
at the same time as the boiler,
unless this is of the sealed
chamber type, or if precise
safety measures are
implemented in the
installation and this also in case
of modifications and/or
additions.
c) the correct functionality of
the smoke evacuation duct;
b) that the calibration
of the burner is not higher than
the rated power of the
boiler;
Warnings for use It
is absolutely forbidden,
because it is dangerous, to
obstruct, even partially,
the air inlets for
ventilation of the room
where the boiler is installed
with cardboard, rags or anything else.
grounding.
a) in mixed boilers,
empty the sanitary
system. In condition
Before starting the boiler,
have professionally qualified
personnel check: a)
that the
data on the plate correspond
to those of the supply networks
(electricity, water, gas);
If you need to
temporarily deactivate the
boiler, proceed as follows:
Do not install the boiler in
damp rooms and, if possible,
above food cooking hobs.
Do not allow children or the
inexperienced to use the
boiler.
The transformation from one
gas to another, which can also
be done with the boiler installed,
must be carried out
exclusively by saunier
duval TACs.
f) that the electrical system
is provided with an effective
It is therefore advisable
that during operation of the
boiler there are no children
or incapable persons without
supervision near it. Do not
wet the boiler with sprays of
water or other liquids.
g) in the case of installation
outdoors, the boiler must
be adequately protected.
Frequently check the water
pressure on the
hydrometer and check that
the indication with the
system cold is always
within the limits prescribed
by the manufacturer.
It is absolutely forbidden to
disconnect or tamper with
the safety devices.
Do not touch hot parts of
the boiler, such as doors,
hood and flue pipe, etc.
which are hot during
and after operation (for a certain
time), since any contact with
them can cause burns.
Do not leave the boiler
inserted unnecessarily when
it is not used for long
periods; in these cases, close
the gas tap and turn off the
power switch.
If frequent drops in pressure
should occur, ask for the
intervention of the saunier duval
CAT as the possible leak
must be eliminated
Machine Translated by Google