To be left with the user
Instructions for Use
Installation and Servicing
4000123924-2 07.03
Hepworth Heating Ltd., Nottingham Road, Belper, Derbyshire. DE56 1JT
Themaclassic
F30E
Fanned Flue Combination Boiler
G.C.No. 47-920-36
Themaclassic
F30E SB
Fanned Flue System Boiler
G.C.No. 41-920-45
Themaclassic
F35E
Fanned Flue Combination Boiler
G.C.No. 47-920-40

Questions and Answers

  • K
    Kevin SanchezAug 14, 2025
    How to troubleshoot a Saunier Duval Themaclassic F30E SB with no display on the control panel?
    • D
      Denise ChristensenAug 14, 2025
      If there is no display on the control panel of your Saunier Duval Boiler, check the 230V supply, the PCB fuse, and the connection between the PCBs.
  • J
    Justin EllisAug 17, 2025
    What to check if the fan does not start on my Saunier Duval Themaclassic F30E SB Boiler?
    • R
      Russell JacksonAug 18, 2025
      If the fan on your Saunier Duval Boiler doesn't start, check the continuity of the fan harness.
  • M
    Mr. Brad JonesAug 21, 2025
    What to do when the fan runs but there are no sparks in my Saunier Duval Themaclassic F30E SB Boiler?
    • J
      Judy WilsonAug 21, 2025
      If the fan runs but there are no sparks in your Saunier Duval Boiler, check the continuity of the ignition components (electrodes and leads) and verify the power supply from the PCB to the ignition unit.
  • L
    Leah HaleAug 25, 2025
    What to do if my Saunier Duval Themaclassic F30E SB Boiler burner doesn't light with a spark?
    • J
      John KellerAug 25, 2025
      If the burner on your Saunier Duval Boiler doesn't light despite an ignition spark, first, ensure the gas taps are turned on. If the issue continues, inspect the wiring. If problems persist, consider replacing the control board (PCB). Also, test the gas control valve.
  • L
    Laurie JonesAug 28, 2025
    Why is my Saunier Duval Themaclassic F30E SB Boiler not giving hot water or heating with a red flashing light?
    • G
      gregory88Aug 28, 2025
      If your Saunier Duval Boiler (F30E/F35E models) isn't providing domestic hot water or central heating, and you see a red flashing warning light with a fault code, check for loose connections on the control board (PCB) and the air pressure switch (both electrical connections and tubes). Also, check the water pressure. Other potential causes include a shortage of air or gas, a faulty temperature sensor, or overheating. Inspect the control or interface boards (PCBs) as well.
  • A
    Amy HenryAug 31, 2025
    How to fix a Saunier Duval Themaclassic F30E SB when the burner lights then goes out (F1 or F4 error)?
    • C
      Craig WebsterAug 31, 2025
      If your Saunier Duval Boiler's burner lights and then goes out (F1 or F4 fault), turn off the power and check the continuity between the flame sense electrode and terminal H2.4 on the control board (PCB). Inspect the connector on the wire's end and ensure the spark electrode is correctly positioned towards the flame. Check the spark electrode and consider replacing it. If the issue remains, the control board (PCB) may be faulty and need replacement.
  • J
    jonesjasonSep 3, 2025
    What causes a Saunier Duval Boiler to light then go out with no flame detected (F1 error)?
    • C
      Corey PruittSep 4, 2025
      If your Saunier Duval Boiler burner lights but then goes out, and no flame is detected (F1 fault), try cleaning the gas filter and the burner.
  • N
    Nancy OsborneSep 7, 2025
    How to increase room temperature with a Saunier Duval Boiler when radiators are luke-warm?
    • M
      michelle97Sep 7, 2025
      If the room temperature is inadequate and the radiators are only luke-warm when using your Saunier Duval Boiler, increase the temperature settings.
  • W
    William MartinSep 10, 2025
    Why is the water luke-warm at the taps with my Saunier Duval Boiler?
    • Y
      yyoungSep 12, 2025
      If the water at the taps is only luke-warm when using your Saunier Duval Boiler, verify that the 3-way valve isn't allowing water to pass into the radiators (the radiators should remain cold in Summer mode).

Summary

Important Information

Gas Safety Regulations

Legal requirements for gas appliance installation and servicing by competent persons.

Electrical Supply Requirements

Appliance must be earthed; wiring must comply with IEE regulations.

Gas Leak or Fault Procedure

Procedure for suspected gas leaks or faults: turn off and consult company.

Frost Protection

Built-in frost protection; system areas need separate frost thermostat.

Draining and Filling

F30 E and F35 E

Procedure for filling the system and resetting the boiler for these models.

F30 E SB Only

Procedure for filling the system and resetting the boiler for the F30E SB model.

Appliance Safety Devices

Air flow rate safety device

Shuts down boiler if flue is obstructed.

Overheating safety

Shuts down boiler in case of overheating.

Maintenance and Servicing

Maintenance and Servicing

Recommendations for regular checks and servicing by a competent person.

User Controls and Lighting

Lighting the boiler

Steps to start the boiler, ensuring supply, gas, and thermostat are ready.

Programmer Instructions for Use

Setting the Time

Step-by-step guide to setting the current time on the programmer.

Override or Advance programmer

How to manually switch heating ON/OFF or override the programmed schedule.

Technical Data

General Information

Statutory Requirements

Installation must comply with UK/IE regulations and standards.

Heating System Design

Domestic Hot Water System Design (F30 E and F35 E Only)

Flow Restrictor

Mandatory fitting of flow restrictor to limit flow rate.

Boiler Location, Flue and Ventilation

Boiler Location

Recommended clearances and mounting requirements for the boiler.

Boiler Preparation and System Connections

Cutting the flue hole

Instructions for cutting the wall opening for the flue system.

Water connection

Connecting system pipework to the fixing jig and isolating valves.

Gas connection

Gas safety regulations and installation requirements.

Boiler Installation

Installing the boiler

Steps for flushing the system, fitting labels, lifting, and connecting boiler to bracket.

Horizontal Rear Flue Installation

Preparing the boiler

Steps for preparing the boiler before fitting the flue assembly.

Installation of Rear Flue assembly

Step-by-step guide to assembling and fitting the horizontal rear flue.

Horizontal Telescopic Top Flue Installation

Installation of telescopic flue assembly

Detailed steps for installing the telescopic flue assembly.

Horizontal Top Flue Installation

Installation of horizontal top flue assembly

Detailed steps for installing the horizontal top flue assembly.

Electrical Connection

Mains Voltage External Controls

Instructions for connecting external controls when mains voltage is used.

Voltage Free External Controls

Warning about applying mains voltage and how to connect external controls.

Commissioning

Adjusting the Central heating output

How to adjust the boiler's central heating output using potentiometers.

Setting flue parameters

Adjusting flue parameters for Themaclassic F 35E for efficiency.

Filling the system

Steps 1-8 for filling the heating system.

Instruct the User

Key instructions and advice to provide to the end user.

Changing Gas Type

Setting the step pressure

Procedure for adjusting step pressure after gas conversion.

Routine Cleaning and Inspection

Products of combustion check

How to check combustion readings using a sampling point.

Service Check and Preparation

Steps for isolating the boiler and preparing for servicing.

Ignition and Flame Sensing Gaps

Checking the correct gaps for ignition and flame sensing electrodes.

Fault Finding

Fault diagnosis

Common faults like no display, no hot water, no central heating.

Fault: No Heating

Troubleshooting steps for when the boiler has no heating.

Fault: Burner lights but goes out

Troubleshooting for burner ignition failure or flame detection issues.

Fault: Burner does not light

Troubleshooting for ignition spark but no burner light.

Fault: Lukewarm tap water

Troubleshooting for hot water temperature issues.

Component testing data

Data for testing gas control valve, three-way valve, and domestic water flow.

Fault: No Hot Water

Troubleshooting steps for when there is no hot water but heating works.

Fault: Burner lights, then goes out

Troubleshooting for flame detected but not correctly.

Fault: Inadequate room temp;lukewarm radiators

Troubleshooting for low heating output or radiators not getting hot.

Fault: Fan does not start

Troubleshooting steps if the fan fails to start.

Fault display codes

Table listing display codes and corresponding faults.

Fault: Fan runs but no sparks

Troubleshooting for fan running but no ignition spark.

Wiring Diagram F30 E

Wiring Diagram F30 E SB

Wiring Diagram F35 E

Replacement of Parts

Spare parts

Saunier Duval Themaclassic F30E SB Specifications

General IconGeneral