To be left with the user
Instructions for Use
Installation and Servicing
4000123924-2 07.03
Hepworth Heating Ltd., Nottingham Road, Belper, Derbyshire. DE56 1JT
Themaclassic
F30E
Fanned Flue Combination Boiler
G.C.No. 47-920-36
Themaclassic
F30E SB
Fanned Flue System Boiler
G.C.No. 41-920-45
Themaclassic
F35E
Fanned Flue Combination Boiler
G.C.No. 47-920-40

Questions and Answers

  • E
    eduardorichardsAug 14, 2025
    How to troubleshoot a Saunier Duval Boiler with no display on the control panel?
    • R
      Raymond TurnerAug 14, 2025
      If there is no display on the control panel of your Saunier Duval Boiler, check the 230V supply, the PCB fuse, and the connection between the PCBs.
  • J
    janebutlerAug 17, 2025
    What to check if the fan does not start on my Saunier Duval Boiler?
    • M
      Mark SmithAug 17, 2025
      If the fan on your Saunier Duval Boiler doesn't start, check the continuity of the fan harness.
  • J
    jeanjacksonAug 20, 2025
    What to do when the fan runs but there are no sparks in my Saunier Duval Themaclassic F35E?
    • L
      Leonard HawkinsAug 21, 2025
      If the fan runs but there are no sparks in your Saunier Duval Boiler, check the continuity of the ignition components (electrodes and leads) and verify the power supply from the PCB to the ignition unit.
  • R
    Robert ObrienAug 25, 2025
    What to do if my Saunier Duval Boiler burner doesn't light with a spark?
    • S
      Susan CortezAug 25, 2025
      If the burner on your Saunier Duval Boiler doesn't light despite an ignition spark, first, ensure the gas taps are turned on. If the issue continues, inspect the wiring. If problems persist, consider replacing the control board (PCB). Also, test the gas control valve.
  • S
    Sharon SmithAug 27, 2025
    Why is my Saunier Duval Boiler not giving hot water or heating with a red flashing light?
    • J
      jaimejonesAug 27, 2025
      If your Saunier Duval Boiler (F30E/F35E models) isn't providing domestic hot water or central heating, and you see a red flashing warning light with a fault code, check for loose connections on the control board (PCB) and the air pressure switch (both electrical connections and tubes). Also, check the water pressure. Other potential causes include a shortage of air or gas, a faulty temperature sensor, or overheating. Inspect the control or interface boards (PCBs) as well.
  • M
    Mary WestAug 31, 2025
    How to fix a Saunier Duval Themaclassic F35E when the burner lights then goes out (F1 or F4 error)?
    • B
      Brian JonesAug 31, 2025
      If your Saunier Duval Boiler's burner lights and then goes out (F1 or F4 fault), turn off the power and check the continuity between the flame sense electrode and terminal H2.4 on the control board (PCB). Inspect the connector on the wire's end and ensure the spark electrode is correctly positioned towards the flame. Check the spark electrode and consider replacing it. If the issue remains, the control board (PCB) may be faulty and need replacement.
  • M
    Monica LindseySep 3, 2025
    What causes a Saunier Duval Themaclassic F35E Boiler to light then go out with no flame detected (F1 error)?
    • B
      Brian ColemanSep 3, 2025
      If your Saunier Duval Boiler burner lights but then goes out, and no flame is detected (F1 fault), try cleaning the gas filter and the burner.
  • D
    Denise JohnstonSep 6, 2025
    How to increase room temperature with a Saunier Duval Boiler when radiators are luke-warm?
    • J
      Joe JohnsonSep 6, 2025
      If the room temperature is inadequate and the radiators are only luke-warm when using your Saunier Duval Boiler, increase the temperature settings.
  • J
    John SmithSep 10, 2025
    Why is the water luke-warm at the taps with my Saunier Duval Themaclassic F35E Boiler?
    • C
      Christopher KingSep 10, 2025
      If the water at the taps is only luke-warm when using your Saunier Duval Boiler, verify that the 3-way valve isn't allowing water to pass into the radiators (the radiators should remain cold in Summer mode).

Summary

Guarantee Registration

Instruction For Use

Important Information

Covers gas safety, testing, CE mark, electrical supply, and heating controls.

Draining and Filling

Provides instructions for draining and refilling the boiler system.

Appliance Introduction

Describes the features and operation of the Themaclassic F boilers.

Appliance Safety Devices

Details safety features like overheat, air flow, and frost protection.

Maintenance and Servicing

Explains recommended servicing intervals and procedures.

User Controls and Lighting

Guides on operating the boiler's temperature selectors and indicators.

Programmer Instructions for Use

Instructions for setting the boiler's timer and operating modes.

Installation Instructions

Technical Data

Provides specifications and performance data for the boiler models.

General Information

Covers important notices, statutory requirements, and certifications.

Heating System Design

Details requirements for designing the central heating system.

Domestic Hot Water System Design

Outlines design considerations for the hot water system.

Boiler Schematic F30 E - F35 E

Illustrates the internal components of the F30E and F35E boiler.

Boiler Schematic F30 E SB

Illustrates the internal components of the F30E SB boiler.

Boiler Location, Flue and Ventilation

Specifies placement and flue installation requirements.

Fixing jig

Details the components and use of the boiler fixing jig.

Boiler Preparation and System Connections

Guides on preparing the boiler and connecting system pipework.

Boiler Installation

Covers the physical installation process of the boiler.

Horizontal Rear Flue Installation

Step-by-step guide for installing the horizontal rear flue.

Horizontal Telescopic Top Flue Installation

Step-by-step guide for installing the telescopic top flue.

Horizontal Top Flue Installation

Step-by-step guide for installing the horizontal top flue.

Electrical Connection

Instructions for wiring the boiler and external controls.

Commissioning

Procedures for initial setup, firing, and system checks.

Changing Gas Type

Instructions for converting the boiler to different gas types.

Bypass Settings

Guidance on adjusting the boiler's internal bypass valve.

Servicing Instructions

Routine Cleaning and Inspection

Details on cleaning components and performing visual inspections.

Fault Finding

Troubleshooting guide for common boiler issues and error codes.

Wiring Diagram F30 E

Electrical wiring schematic for the F30E model.

Wiring Diagram F30 E SB

Electrical wiring schematic for the F30E SB model.

Wiring Diagram F35 E

Electrical wiring schematic for the F35E model.

Replacement of Parts

Step-by-step instructions for replacing various boiler components.

Spare Parts

List of common spare parts with part numbers.

Saunier Duval Themaclassic F35E Specifications

General IconGeneral
Fuel TypeNatural gas
Warranty2 years
TypeWall-mounted gas boiler
Power Output24 kW
EfficiencyA
ERPA Rated
Output24.4 kW