Connection
03:04 Issue 2.0 en-GB 10
C4066
Connection of power supply to the engine management system and instrumentation
2.1 (battery).
Note:
Connect the junction box directly to the battery and not to the starter motor. Use
twisted pair electrical cables and do not make the electrical cable longer than neces-
sary. The cable cross-sectional area must be at least 2.5 mm².
If the system has a safety device unit (SDU), 2 separate groups of batteries must be
used. If the system does not have a safety device unit, pins 1-4 must be connected to
the same group of batteries.
C4062
Connection to engine harness-to-harness connector C4001.
Pin Description I/O
1 30 voltage, 24 V -
2 Ground (battery negative terminal) -
3 30 voltage, 24 V -
4 Ground (extra battery negative terminal) -
C4068
C4067
C4062
C4066
SDU
SDU
C4058
C4059
C4060
C4061
C4052
C4056
1
2
3
4
Gat
e
w
a
y
C4001
C4053
DCU
393 368
Connecting the junction box.