INSTALLATION
MANUAL
© Scania CV AB 2017, Sweden
Connection
03:04 Issue 2.0 en-GB 9
Junction box, connection
Minimum connection
The minimum connection required for the system to function is for the pins on har-
ness-to-harness connector C4066 to be connected.
Connecting the throttle control
Please refer to 03:01 Electrical system for information on how to connect the throttle
control to the engine control unit. If the throttle control is connected to the engine
control unit, secondary throttle control cannot be used.
If the throttle control is to be controlled via the main display, the following must be
connected:
Passive throttle control
Connect pins 1 and 2 in harness-to-harness connector C4068, according to C4068
.
Active throttle control
If active throttle control is to be connected, the throttle control must be grounded.
Bridge C4066 pin 2 and C4068 pin 3, and connect C4068 pin 3 to the electrical
ground point of the throttle control.
-
C4068-3
C4066-2
-
+
392 503
Connecting active throttle control.