INSTALLATION
MANUAL
© Scania CV AB 2017, Sweden
Auxiliary display
03:04 Issue 2.0 en-GB 105
Station Priority
Enter the priority the auxiliary panel should have on the network. This setting con-
trols how the auxiliary panel works together with other auxiliary panels on the net-
work.
How to select the correct priority:
Select Priority 1 if this auxiliary display is the only auxiliary display on the net-
work.
Select Priority 1 or Priority 2 if there are other auxiliary displays on the network
than this auxiliary display.
Select Priority 3 if this auxiliary display should only be used for monitoring.
Priority 1 Priority 2 Priority 3
Description Select this option if this auxiliary display should
have the highest prority, e.g. if it is to be located
in the engine compartment. Also choose Priority
1 if there is only one auxiliary display on the net-
work.
Select this option if this auxiliary display should
have a lower prority, e.g. if it is to be located on
the bridge.
Select this option if this auxiliary display is to be
located in a public area, where no commands
should be executed.
Function to take
control
An auxiliary display with priority 1 can always
take control from the auxiliary display which is
the active display. If the operator tries to execute
a command on an auxiliary display with
priority 1 which is not the active display, it will
immediately become the active display and exe-
cute the command.
An auxiliary display with priority 2 can take con-
trol from an active display with priority 1 or 2 if
confirmed on the active display.
An auxiliary display with priority 3 can never be-
come an active display.