User Manual, Power contactors, series CT1115/08 and CT1130/08
Rev. 2.2 Page 23/26
Reassembly of the fixed contacts
Control the position of the nuts prior to assembly of the new fixed con-
tacts.
Replace the fixed contacts and push them into the locked position.
Retighten the four M6 screws
(Torque = 7 Nm).
Check that the cable lug is tight.
Take special care concerning the correct position
of the wires, close to the plastic (CT1115/08).
Take special care concerning the correct position
of the wires (CT1130/08).
Reinstall the Lower Module
Replace the protection cap for the auxiliary switches
Replace the protection cap for the magnetic drive
Replace the Upper Module and secure it. Reconnect the main ca-
bles/current bars.