3.3 Faults
A fault in the power supply system is usually caused by a blown fuse.
The following functions are protected by self-resetting fuses:
F
Exit step
F
Sensor lines to the DT ... control and switch panel
If there is a fault with the step, it must not be operated for a period of 1 mi-
nute. The fuse resets automatically during this period.
For faults with the DT ... control and switch panel, the entire system must be
switched off from the battery cut-off and turned on again after about 1 mi-
nute.
Please contact our customer service department if you cannot rectify the
fault using the following table.
If this is not possible, e.g. if you are abroad, you can have the Electroblock
repaired at a specialist workshop. In this case, you must ensure that the
warranty is not invalidated by incorrect repairs being carried out. Schaudt
GmbH shall not accept any liability for damage resulting from such repairs.
Fault Possible cause Remedy
Living area battery is not
charged during 230V ope-
No mains voltage Switch on the automatic
fuse in the vehicle
ration (battery voltage
Have the mains voltage
cons
an
y
e
ow
.
checked
Defective Electroblock Call customer service
Living area battery is over-
charged during 230V ope-
ration (battery voltage
constantly above 14.5 V)
Defective Electroblock Call customer service
Starter battery is not char- No mains voltage Switch on the automatic
ged during 230V opera-
fuse in the vehicle
tion (battery voltage con-
stantly below 13.0 V)
Have the mains voltage
checked
Defective Electroblock Call customer service
Living area battery is not
Defective alternator Check the alternator
charged during mobile
No voltage on D+ input Check fuses and wiring
below 13.0 V)
Defective Electroblock Call customer service
The living area battery is
overcharged during mo-
bile operation (battery vol-
tage constantly above
14.3 V)
Defective alternator Check the alternator
The refrigerator does not
work during mobile opera-
No power supply to the re-
frigerator
Check fuse and wiring
tion
Defective Electroblock Call customer service
Defective refrigerator Check the refrigerator
Flat vehicle fuses
Self-resettingfuses