4 – MOUNTING AND INSTALLATION COD: 60S12/24.B.2021
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
23
Low pressure
connections –
max 3 bar
• Connection between seawater intake – Mesh
filter – non-return valve inlet – pump group
Armorvin reinforced hose PN6
with 16mm internal diameter
• Connection between the discharge of the
watermaker – through hull discharge fittings of
the vessel
Armorvin reinforced hose PN6
with 16mm internal diameter
Medium pressure
connections –
max 10 bar
• Connections fresh water pressurized system–
carbon filter-backflow valve outlet–pump inlet
• Connections pump outlet-5 microns filter–
watermaker inlet.
Rubber reinforced hose PN 10
minimum, internal diameter
16 mm.
Low pressure
connections -
max 3 bar
• Watermaker - fresh water tank
¼’’ fittings, Small plastic blue
hose 6x8mm provided within
the scope of supply
PUMP CONNECTIONS:
Connect the in/out hose to the pump as follows:
PUMP IN AND OUT
FIG. 4-2
CAUTION
The pump has to be placed as close as possible to the seawater intake and as low as
possible respect to the seawater level; furthermore, it is recommended to avoid long and
convoluted path of the connection hoses.