Installation, use and maintenance manual
Model.: SMART 100
Matriculation number: 100S12/24D
Year of construction: 2006
Schenker Italia
Via Delle Repubbliche Marinare, 67
80147 Naples Italy
Tel. +39 081 5593505
Fax. +39 081 5597372
E-mail: info@schenker.it
WWW.schenkerwatermakers.com
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
SMART 100
Digital 12/24 V dc

Table of Contents

Questions and Answers

  • A
    Ana RobertsonAug 8, 2025
    What to do if the Schenker Water Filtration System pump starts but blocks in high pressure?
    • B
      Brandon WalshAug 8, 2025
      If your Schenker Water Filtration System pump starts but then blocks in high pressure, this could be due to several reasons: a hydraulic block (perform reset procedure), dirty filters (replace filters), or obstructed membranes (perform washing procedure). If the problem persists, it may be due to a commutation system block, in which case you should contact customer service.
  • D
    David GibsonAug 12, 2025
    How to fix a Schenker Water Filtration System when the pump doesn’t start?
    • M
      Michelle ArroyoAug 12, 2025
      If the pump of your Schenker Water Filtration System doesn’t start, it might be due to a disconnected or burned pump pressure switch (restore or replace the pump pressure switch). You can also try activating the by-pass.
  • J
    jessicasharpAug 16, 2025
    Why is my Schenker Water Filtration System showing low production with high pressure?
    • I
      iarmstrongAug 16, 2025
      Low production with high pressure (> 13 Bar) in your Schenker Water Filtration System could be caused by dirty filters (replace filters) or obstructed membranes (perform washing procedure). It could also be due to cold inlet water, in which case you should contact customer service.
  • A
    Alexis GrossAug 20, 2025
    What to do if Schenker Water Filtration Systems pump starts and stops?
    • J
      Jonathan WilliamsAug 21, 2025
      If your Schenker Water Filtration System's pump starts and stops intermittently during operation, it could be due to a pump pressure switch not correctly set (set pump pressure switch). Another cause might be dirty filters or membranes (clean or replace).
  • J
    Jennifer CoxAug 25, 2025
    Why is my Schenker Water Filtration System showing low production with normal or low pressure?
    • M
      Mary Barton MDAug 26, 2025
      Low production with normal or low pressure in your Schenker Water Filtration System could be due to a low battery (check battery charge) or air within the system (purge the air out of the system). It could also be caused by loss of sealing systems, in which case you should contact customer service.
  • T
    Todd BryantAug 29, 2025
    How to troubleshoot a loss in the Schenker Water Filtration System?
    • J
      Justin CastilloAug 29, 2025
      If you observe a loss in your Schenker Water Filtration System, check for loose fittings and tighten them. If the ERS leaks, contact customer service.
  • F
    Frederick HarrellSep 2, 2025
    What causes metal noise in a Schenker Water Filtration System pump?
    • T
      tylerevansSep 2, 2025
      If you hear a metal noise from the pump of your Schenker Water Filtration System, it may be due to pump cavitation. Check the causes of the absence of water flow at the pre-pump inlet.

Schenker SMART 100 Specifications

General IconGeneral
BrandSchenker
ModelSMART 100
CategoryWater Filtration Systems
LanguageEnglish