MODULAR 60
Analogic 12/24 V dc

Table of Contents

Questions and Answers

  • S
    simsmistySep 4, 2025
    What causes metal noise in Schenker MODULAR 60 pump?
    • G
      Gregory ShawSep 4, 2025
      If you hear a metal noise from the pump of your Schenker Water Filtration System, it could be due to pump cavitation. Check the causes of the absence of water flow at the pre-pump inlet.
  • E
    eric06Sep 18, 2025
    What to do if I hear metal noise from the Schenker Distilling equipment pump?
    • M
      Mark ThompsonSep 18, 2025
      If you hear metal noise from the pump of your Schenker Distilling equipment, it could be due to pump cavitation. Check for causes of absence of water flow at the pre-pump inlet.
  • D
    Derek YangSep 16, 2025
    What causes a loss in the Schenker Distilling equipment system?
    • H
      hjonesSep 16, 2025
      If there is a loss in your Schenker Distilling equipment, it could be due to loose fittings or ERS leaks. Try tightening the fittings. If the loss continues, contact customer service.
  • A
    Anthony SinghSep 14, 2025
    Why won’t the pump start on my Schenker Distilling equipment?
    • R
      Raymond PriceSep 14, 2025
      If the pump on your Schenker Distilling equipment doesn’t start, it could be due to a disconnected or burned pump pressure switch, or an electronic issue. Try restoring or replacing the pump pressure switch. You can also activate the bypass.
  • J
    Justin SmithSep 13, 2025
    How to troubleshoot low production with normal pressure in Schenker Distilling equipment?
    • J
      Jessica MaynardSep 13, 2025
      If your Schenker Distilling equipment shows low production with normal or low pressure, it might be due to a low battery, air within the system, or loss of sealing systems. Check the battery charge and purge the air out of the system. If the issue remains, contact customer service.
  • S
    Shawn StewartSep 12, 2025
    Why does the pump in my Schenker Distilling equipment keep starting and stopping?
    • J
      jeffrey31Sep 12, 2025
      If the pump in your Schenker Distilling equipment temporarily switches off during operation, causing a start-and-stop issue, the pump pressure switch might not be correctly set, or the filters or membranes could be dirty. Try setting the pump pressure switch and cleaning or replacing the filters or membranes.
  • K
    Kyle VaughanSep 9, 2025
    What to do if Schenker Distilling equipment starts but goes into alarm after 25 seconds?
    • T
      Tammy WalkerSep 9, 2025
      If your Schenker Distilling equipment starts but goes into alarm after about 25 seconds, it could be in hydraulic block. Check if the pressure gauge indicates above 9-10 bar and the pump starts and stops continuously. If so, carry out the reset procedure and restart the system. If it still blocks, activate the system manually using the bypass. If the system then works correctly, it might be a pressure switch issue. Disconnect the two cables of the pressure switch from the PCB of the controller and connect them to a meter in ohm position. The pressure switch should give a closing signal followed by an opening signal every 3-4 seconds. If the signal is always open or always closed, replace the pressure switch.
  • S
    Suzanne HowardSep 7, 2025
    Why is there low production and high pressure in my Schenker Distilling equipment?
    • A
      Amy RobertsSep 7, 2025
      If your Schenker Distilling equipment is showing low production with high pressure (above 9 Bar), the cause might be clogged filters, clogged membranes, or cold inlet water. Try replacing the filters and performing a washing procedure. If the problem persists, contact customer service.
  • K
    Karen WatsonSep 5, 2025
    What to do if the Schenker Distilling equipment pump starts but the system suddenly blocks in high pressure?
    • W
      Wendy SandersSep 5, 2025
      If your Schenker Distilling equipment's pump starts but then blocks due to high pressure, it could be due to a hydraulic block, dirty filters, obstructed membranes, or a block in the commutation system. You can try performing a reset procedure or replacing the filters. A washing procedure may also help. If the issue persists, it's best to contact customer service.
  • R
    robertsaundersAug 21, 2025
    Why is there low production with normal pressure in my Schenker Water Filtration Systems?
    • J
      John WoodardAug 21, 2025
      If your Schenker Water Filtration System has low production with normal or low pressure, it might be due to a low battery, air within the system, or loss of sealing systems. Check the battery charge and purge the air out of the system. If the problem persists, it may be necessary to contact customer service.

Summary

General Warnings & Information to the Recipient

Important information

Stresses manual reading for safety, copyright, and directive compliance.

Safety warnings

Lists crucial safety precautions, protective gear, and operational risks to avoid.

Mounting and Installation

General criteria

Outlines key considerations for planning the installation, including component placement and passages.

Water intakes and discharges

Lists required water intake and discharge points for proper installation.

Seawater intake

Details ideal and alternative methods for seawater intake, including fittings and filters.

Hydraulic connections

Illustrates and details all necessary hydraulic connections and hose specifications.

Electric connection

Introduces the electrical connection process, emphasizing qualified personnel.

Electric connections: wires (Modular 60 12;24 V DC)

Details wire selection, cable lengths, and connection tables for the electrical hookup.

Electric layout scheme (12;24 V DC)

Presents the comprehensive electrical wiring diagram for the system.

Functioning and Use

First start up procedure

Outlines the essential steps for the initial startup and air purging of the system.

Preliminary checks before proceeding with the startup procedure

Lists crucial checks that must be performed before initiating the startup sequence.

Start up

Provides a detailed step-by-step guide for the system's startup procedure.

Normal operating procedure

Lists necessary checks before beginning normal operation of the watermaker.

Normal operating procedure with automatic washing on (advisable procedure)

Step-by-step guide for normal operation with the recommended automatic washing.

Maintenance (Routine and Extraordinary)

Antifreeze procedure (Winterizing procedure in cold climate - under 5°C)

Instructions for applying antifreeze to protect the system from freezing.

Troubleshooting

Failure chart

A table listing common issues, their causes, and recommended remedies.

Electronic issues and their solution

Addresses specific electronic problems and provides solutions for them.