EasyManua.ls Logo

Schenker MODULAR 60 - User Manual

Schenker MODULAR 60
53 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
COD: 60M12/24.A.2018
Installation, use and maintenance manual
Model.: Modular 60
Matriculation number: 60M12/24A
Year of construction: 2000
Schenker Italia
Via Delle Repubbliche Marinare, 67
80147 Naples Italy
Tel. +39 081 5593505
Fax. +39 081 5597372
E-mail: info@schenker.it
WWW.schenkerwatermakers.com
THE PRESENT MANUAL BELONGS TO - Schenker Italia - ALL RIGHTS RESERVED
MODULAR 60
Analogic 12/24 V dc

Table of Contents

Questions and Answers

  • R
    riveraannaSep 2, 2025
    How to troubleshoot Schenker Water Filtration Systems when the pump doesn’t start?
    • L
      Leonard DeanSep 2, 2025
      If the pump of your Schenker Water Filtration Systems doesn’t start, the pump pressure switch may be disconnected or burned, or there may be an electronic issue. Restore or replace the pump pressure switch and activate the by-pass.
  • B
    Brittney HartAug 31, 2025
    What to do if Schenker MODULAR 60 Water Filtration Systems starts but alarms after 25 seconds?
    • D
      danny68Aug 31, 2025
      If the Schenker Water Filtration System starts when you press the start button but goes into alarm after about 25 seconds, check if the watermaker is in hydraulic block (pressure indicated by the pressure gauge above 9-10 bar and pumps off). In this case, carry out the reset procedure and restart the system. Also, disconnect the pressure switch from the terminal board, activate the system manually by inserting the bypass, and measure the operation of the pressure switch with a tester in "ohm" position. The pressure switch must give, under normal conditions, a closing signal followed by an opening signal, every 3-4 seconds. If the signal is always open or always closed, the pressure switch must be replaced.
  • J
    John MossAug 29, 2025
    Why does my Schenker MODULAR 60 Water Filtration Systems pump keep starting and stopping?
    • L
      Laurie CooperAug 30, 2025
      If the pump in your Schenker Water Filtration System temporarily switches off during operation, causing a start and stop phenomenon, it could be due to an incorrectly set pump pressure switch, or dirty filters or membranes. Set the pump pressure switch correctly and clean or replace the filters or membranes.
  • J
    Joshua AndersonAug 28, 2025
    How to fix a loss in Schenker MODULAR 60?
    • J
      Jamie DavenportAug 28, 2025
      If you notice a loss in your Schenker Water Filtration System, check for loose fittings and ERS leaks. Tighten any loose fittings. If the issue persists, contact customer service.
  • K
    Krista HoganAug 26, 2025
    Why Schenker Water Filtration Systems does not start when pushing the start button?
    • Z
      zachary90Aug 26, 2025
      If your Schenker Water Filtration System doesn't start when you push the start button, verify that the bypass is excluded (selector turned anticlockwise) and that the pumps are activated (pump 1 and pump 2 selectors turned clockwise). Also, check that the system is properly electrically connected according to the diagram in the manual, and that the main magnetothermal switch is activated. Ensure power is reaching the electrical box by measuring the voltage with a tester between the + and - terminals. If the battery charge is insufficient, charge the batteries and try again. Finally, check all the electrical connections between the remote panel and microcomputer; if necessary, replace the microcomputer box, the connection cable, or the remote panel.
  • W
    wisekatherineAug 25, 2025
    What causes low production and high pressure in Schenker Water Filtration Systems?
    • A
      acarrollAug 25, 2025
      Low production with high pressure (above 9 Bar) in your Schenker Water Filtration System can be caused by dirty filters, obstructed membranes, or cold inlet water. Replace the filters and perform the washing procedure. If the problem persists, contact customer service.
  • A
    Amber WebbAug 22, 2025
    What to do if Schenker Water Filtration Systems pump starts but blocks in high pressure?
    • E
      Eric RiveraAug 23, 2025
      If the pump in your Schenker Water Filtration System starts but the system suddenly blocks at high pressure, the cause may be a hydraulic block, dirty filters, obstructed membranes, or a blocked commutation system. Try performing a reset procedure and replacing the filters. You can also perform a washing procedure. If the issue continues, contact customer service.

Summary

General Warnings & Information to the Recipient

Important information

Stresses manual reading for safety, copyright, and directive compliance.

Safety warnings

Lists crucial safety precautions, protective gear, and operational risks to avoid.

Mounting and Installation

General criteria

Outlines key considerations for planning the installation, including component placement and passages.

Water intakes and discharges

Lists required water intake and discharge points for proper installation.

Seawater intake

Details ideal and alternative methods for seawater intake, including fittings and filters.

Hydraulic connections

Illustrates and details all necessary hydraulic connections and hose specifications.

Electric connection

Introduces the electrical connection process, emphasizing qualified personnel.

Electric connections: wires (Modular 60 12;24 V DC)

Details wire selection, cable lengths, and connection tables for the electrical hookup.

Electric layout scheme (12;24 V DC)

Presents the comprehensive electrical wiring diagram for the system.

Functioning and Use

First start up procedure

Outlines the essential steps for the initial startup and air purging of the system.

Preliminary checks before proceeding with the startup procedure

Lists crucial checks that must be performed before initiating the startup sequence.

Start up

Provides a detailed step-by-step guide for the system's startup procedure.

Normal operating procedure

Lists necessary checks before beginning normal operation of the watermaker.

Normal operating procedure with automatic washing on (advisable procedure)

Step-by-step guide for normal operation with the recommended automatic washing.

Maintenance (Routine and Extraordinary)

Antifreeze procedure (Winterizing procedure in cold climate - under 5°C)

Instructions for applying antifreeze to protect the system from freezing.

Troubleshooting

Failure chart

A table listing common issues, their causes, and recommended remedies.

Electronic issues and their solution

Addresses specific electronic problems and provides solutions for them.

Schenker MODULAR 60 Specifications

General IconGeneral
BrandSchenker
ModelMODULAR 60
CategoryWater Filtration Systems
LanguageEnglish

Related product manuals