13. Troubleshooting
Fault Possible cause Remedy
The compressor does
not start.
No supply voltage.
Insu󰀩cient supply voltage.
Outside temperature is too
low.
Motor is overheated.
Check cable, power plug, fuse
and socket.
Avoid extension cables that are
too long. Use extension cables
with su󰀩cient wire cross-sec-
tion.
Do not operate below +5° C
outside temperature.
Allow the motor to cool down. If
necessary, eliminate the cause
of overheating.
The compressor
starts but there is no
pressure.
The non-return valve leaks.
The seals are damaged.
Replace non-return valve.
Check seals, have broken
seals replaced at a specialist
workshop.
The compressor starts,
pressure is shown on
the pressure gauge,
but the tools do not
start.
The hose connections
have a leak.
A quick-lock coupling has
a leak.
Check compressed air hose
and tools, replace if necessary.
Check quick coupling, replace if
necessary.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Scheppach Air Force 4 and is the answer not in the manual?

Scheppach Air Force 4 Specifications

General IconGeneral
BrandScheppach
ModelAir Force 4
CategoryAir Compressor
LanguageEnglish

Related product manuals