14. Troubleshooting
Fault Possible cause Remedy
Motor does not start
No mains voltage (power failure) Check fuse
Connection cable defective
Replace cable or have cable checked (elec-
trician)
no longer use defective cables
Motor or switch faulty
to solve the problem, contact the manufactur-
er or a company named by him
Unusual vibrations
Damaged mixer Replace mixer
Mixing shaft damaged
to solve the problem, contact the manufactur-
er or a company named by him
Wrong mixing material
Wrong processing Observe the manufactur-
er’s processing instructions
The device starts up, but
blocks when the load is
low and may switch o
automatically.
Extension cable too long or
cross-section too small.
Extension cable must be at least 1.5 mm² with
a maximum length of 25 m.
Socket too far from the main con-
nection and too small cross-sec-
tion of the connection cable.
For longer cables, cross-section must be at
least 2.5 mm².