Operating Instructions for Actuators Type AB with
Control Unit
OM-ENGLISH-ABCSC.V1.2-16xx-V2.02-2023.04.27

Table of Contents

Question and Answer IconNeed help?

Do you have a question about the SCHIEBEL AB5 and is the answer not in the manual?

SCHIEBEL AB5 Specifications

General IconGeneral
BrandSCHIEBEL
ModelAB5
CategoryController
LanguageEnglish

Summary

Hazard Warnings

General Actuator Information

Overview of Actuator Components

Provides a general overview of the actuator and its components, including the SMARTCON control unit and operating unit.

Protection Class Details

Details the IP protection system (IP66/IP65) for actuators and emphasizes correct cable gland usage.

Actuator Protection Devices

Covers electromechanical, mechanical, and electrical protection devices integrated into the actuator for safe operation.

Installation Instructions

Mechanical Connection Procedures

Details the steps for mechanically connecting the actuator to fittings or gears, including greasing and cleaning.

Electrical Connection Guidelines

Covers the process of electrically connecting the actuator, emphasizing safety precautions and proper wiring.

Commissioning Procedures

Commissioning General Steps

General guidelines for commissioning, including mechanical pre-adjustment, position indication, and end position adjustments.

Switching to Manual Operation

Describes how to switch the actuator to manual operation using the hand lever and wheel, and safety considerations.

Mechanical Default Settings

Details the mechanical pre-adjustment steps for actuators with a design potentiometer for travel, including setting values.

Mechanical Position Indication Adjustment

Explains how to adjust the mechanical position indication in conjunction with the mechanical pre-setup.

SMARTCON Control Unit Parameterization

Guides on parameterizing the SMARTCON control unit after the actuator pre-setup, emphasizing torque and end position settings.

Setting End Positions (Potentiometer)

Details the process of setting the end positions (OPEN and CLOSE) for actuators using a potentiometer for travel.

Setting End Positions (Switch)

Provides instructions for setting end positions for actuators using a switch for travel, including adjustments for roller-type counters.

Maintenance and Monitoring

Battery and Fuse Management

Battery Replacement Guide

Explains how to replace the button cell battery for the real-time clock and counter readings, emphasizing safety.

Fuse Specifications and Location

Details the location and types of fuses used in the SMARTCON control unit and their specifications.

Technical Data