Do you have a question about the Schlumberger CAMERON LEDEEN VA Series and is the answer not in the manual?
Temperature Range | -40°C to +85°C (-40°F to +185°F) (dependent on model and components) |
---|---|
Control Signal | 4-20mA, HART |
Power Supply | 24 VDC or 120/240 VAC |
Certifications | ATEX, IECEx, CSA |
Material | Stainless Steel and Aluminum |
Explains warning symbols used for safe operation.
Emphasizes using genuine parts to avoid warranty issues.
Details necessary qualifications and training for maintenance staff.
Outlines customer responsibility for damages from material degradation.
States customer responsibility for damages during instrument failure.
Holds customer responsible for damages from unauthorized modifications.
Provides instructions for safe and environmentally sound disposal.
Details checks and procedures for safe power supply connection.
Lists essential safety recommendations for operation and maintenance.
Guidelines for handling to prevent electrostatic discharge.
Explains actuator marking according to the ATEX directive.
Describes the information found on the actuator nameplate.
Steps for verifying received material against documentation.
Guidelines for storing the actuator to maintain its condition.
Instructions for safe lifting and handling of the actuator.
Detailed steps for attaching the actuator to the valve.
Guides on adjusting mechanical stops for stroke control.
Procedures for connecting and starting up the actuator.
Outlines scheduled checks and lubrication for routine maintenance.
Steps for addressing malfunctions or leakages requiring special attention.
Detailed instructions for replacing dynamic seals.
Detailed instructions for taking the actuator apart.
Detailed instructions for putting the actuator back together.
Procedures for adjusting and checking the actuator after assembly.