Adaptive Function
With this feature enabled the room will already have reached the target/setpoint
temperature at the beginning of an event.
After just a few days, the adaptive function will have automatically calculated how
much earlier the heating must be turned on/o to achieve this.
Select “OFF” if you simply want the heating to start at the beginning of an event.
1. Tap the “Menu” button on the home screen.
2. Scroll down and tap the “Engineer Settings” button.
3. Tap the “Adaptive Function” button.
4. Tap the “OFF/ON” button to the setting you prefer and confirm with the “√”
button.
5. The thermostat will automatically return to “Engineer Settings”.