4 Maintenance and servicing
SCHMIDT
®
ElectricPress 343-345 – V2.1 17
4.2 Adjusting the force measurement
Since the force-measuring system is usually used for measuring
characteristic quantities relevant to quality, it should be calibrated and, if
necessary, adjusted at reasonable intervals established by the owner. EN
ISO 9001 (Quality management systems - Requirements) makes a
calibration of the system mandatory at regular intervals.
Calibration is also offered as a service by the SCHMIDT Customer Service.
4.3 Lubricating the gear
The lubrication of the spindle is stroke-dependent. Depending on the
configured operating profile, the point in time for the next lubrication is
calculated. When the given time has come, the control will request you to
lubricate.
For further information, refer to the "Instructions for Use - SCHMIDT Manual
workstation" respectively the "Assembly Instructions - SCHMIDT
Components for automation".
For the gear lubrication, the lubricant must be pressed in through the
lubrication nipples.
Remove the cover over the face side lubrication nipple.
Using the grease gun, press grease into the lubrication nipples.
Reinsert the cover of the face side lubrication nipple.