11. MAINTENANCE INSTRUCTIONS
11.1 After use and before performing
maintenance, unplug and disconnect
the solar battery maintainer (see
sections 6, 7 and 8).
11.2 Use a dry cloth to wipe all battery
corrosion and other dirt or oil from the
battery clips, cords and the solar panel.
11.3 The solar battery maintainer uses a glass
substrate; handle with care.
11.4 Always keep the glass surface clean
using a soft cloth in order to ensure its
maximum output.
11.5 Ensure that all of the solar battery
maintainer components are in place and
in good working condition, for example,
the plastic boots on the battery clips.
11.6 Servicing does not require opening the unit,
as there are no user-serviceable parts.
11.7 All other servicing should be performed by
qualied service personnel.
12. MOVING AND STORAGE INSTRUCTIONS
12.1 Store the solar battery maintainer
unplugged, in an upright position.
12.2 Store inside, in a cool, dry place.
12.3 Do not store the clips clipped together, on
or around metal, or clipped to cables.
12.4 If the solar battery maintainer is moved
around the shop or transported to
another location, take care to avoid/
prevent damage to the cords, clips and
solar battery maintainer. Failure to do so
could result in personal injury or property
damage.
13. SPECIFICATIONS
Peak power output ................................................................................................. 2.4 Watt
Tested under standard conditions
............................................. AM1.5, 100mW/cm
2
, 25°C
Optimum working voltage
.......................................................................................17.50 V
Optimum working current
...................................................................................... 130 mAh
Operating temperature
........................................................-40° F185° F (-40° C85° C)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Schumacher Electric SP-200 and is the answer not in the manual?

Schumacher Electric SP-200 Specifications

Power Output IconPower Output
peak power output2.4 Watt
optimum working voltage17.50 V
optimum working current130 mAh
Operating Environment IconOperating Environment
tested under standard conditionsAM1.5, 100mW/cm[2], 25°C
operating temperature-40° F–185° F (-40° C–85° C)