Assembly
05.00 | ELB | Montage- und Betriebsanleitung | en | GAS 376437
85
6.1.2.3 LE100 M12 incremental measuring system
Description LE100 M12
Operating voltage [VDC] 5 ± 5 %
Output signal Sin, Cos
Signal amplitude [Vss] 1 ± 10 %
Offset sine/cosine [V] 2.5 ± 0.5 %
Signal period [µm] 1000
Reference signal, periodic [mm] 20
Distance reading head - steel tape 0.05 - 0.2
Pin Configuration
1 SIN-
2 SIN+
3 COS-
4 COS+
5 REF+
6 REF-
7 GND
8 Vcc
9 N.C.
10 N.C.
11 N.C.
12 N.C.