Cuber System Information
Overall System Type:
•
Refrigeration: Mechanical, either air cooled or water cooled
•
Water System: Inlet water float valve fills reservoir continuously. Purge solenoid valve opens to
discharge some reservoir water once per cycle.
•
Control System: Electronic
•
Harvest cycle sensor: Conductivity probe
•
Water full/empty sensor: Conductivity probe
•
Bin Control: Curtain Switch
•
Ice type: Unified
•
Harvest system: Hot gas defrost with mechanical assist
Electrical Components:
•
Compressor
•
Contactor
•
Water Pump
•
Purge or purge Valve
•
Fan Motor(s)
•
Fan motor pressure control
•
High pressure cut out
•
Harvest Assist Solenoid
•
Hot Gas Valve
•
Controller
•
Transformer – 12v AC for the controller only
•
Water Sensor
•
Ice Thickness Sensor
•
Curtain Switch
May 2008