Performance Information
Ice per cycle: 1 lb
Water drained / cycle: Varies by harvest cycle
length and purge setting. Typical amounts are @
70/50 = 52 oz. @ 90/70 = 13 oz
Compressor amps: 2.6 - 3.2
March 2010
Page 21
CU50
Service Manual
Freeze Cycle, Minutes
Air Temperature
100 90 80 70 60 50
Water
Temperature
100 37-38 36-37 34-35 32-33 31-32 29-30
90 36-37 35-36 33-34 31-32 30-31 28-29
80 36-35 32-33 30-31 28-29 27-28 26-27
70 32-33 28-29 27-28 25-26 23-24 22-23
60 27-28 25-26 24-25 22-23 20-21 19-20
50 20-21 19-20 18-19 17-18 16-17 15-16
40 18-19 17-18 16-17 15-16 15-16 15-16
Harvest Cycle, Seconds
Air Temperature
100 90 80 70 60 50
Water
Temperature
80 -100 55-60 60-70 70-80 80-90 90-100 110-115
70 - 80 65-75 70-80 75-85 85-95 95-105 115-120
50 - 70 70-80 75-85 85-95 125-135 140-150 160-170
40 - 50 100-120 115-125 130-140 150-170 180-200 210-230
Total Cycle, Minutes
Air Temperature
100 90 80 70 60 50
Water
Temperature
100 38-39 37-38 36-37 34-35 33-34 31-32
90 38-39 36-37 35-36 33-34 32-33 30-31
80 37-38 33-34 31-32 30-31 29-30 27-28
70 33-34 29-31 28-29 26-27 25-26 24-25
60 29-30 27-28 25-26 24-25 22-23 21-22
50 21-22 20-21 19-20 19-20 19 18-19
40 20-21 19-20 19 18-19 19 19-21