4.3. Switching off
n Stop and disconnect the equipment from the sockets (fig. A - No. 12).
o Allow the engine to run on no-load for 1 or 2 minutes.
p Turn the ignition key (fig. A - No. 10) to the « O » position: The generating set stops.
q Shut off the fuel tap (fig. A - No. 6 & fig. C - No. 1).
Always make sure that the generating set is properly ventilated.
Even after it has stopped, the engine continues to give off heat.
Warning
5. Safety features
5.1. Circuit breaker
The set's electrical circuit is protected by one or more magnetothermal, differential or thermal cut-out switches. In the event of an
overload and/or short circuit, the supply of electrical energy may be cut.
If necessary, replace the circuit breakers in the generating set with circuit breakers with identical nominal ratings and specifications.
5.2. Oil cut-out
If there is no oil in the engine sump or if the oil pressure is low, the oil safety mechanism automatically stops the engine to prevent any
damage.
If this occurs, check the engine oil level and top it up if necessary before looking for any other cause of the problem.
6. Maintenance schedule
6.1. Reminder of use
The maintenance operations to be carried out are described in the maintenance schedule. The interval for this is supplied as a guide
and for generating sets operating with fuel and oil which conform to the specifications given in this manual.
If the generating set is used under extreme conditions, the interval between the maintenance operations must be shortened.
6.2. Maintenance table
Component
Operations to be
carried out when the
expiry date is reached
Each time it is
used
Every
Year
Or
every 25 hours
Every
Year
Or
every 100
hours
Every
Year
Or
every 200
hours
Every
Year
Or
every 500
hours
Screws and bolts Check
Engine oil
Check the level
Change
Oil filter Replace
Fuel filter Replace
Air filter
Check
Clean**
**
Replace***
***
Starter battery Check
Spark plugs
Check - Clean
Replace
Generating set Clean
Valves* Have checked*
*
Starter* Have checked*
*
* Operation(s) to be entrusted to one of our dealers. ** Foam element. *** Paper element.
If used in dusty conditions, clean the air filter more frequently.
7. Maintenance procedures
Before carrying out any maintenance operation:
- switch off the generating set.
- disconnect the cap(s) of the spark plug(s) and disconnect the starter battery (if fitted).
Warning
Only use original parts or equivalent parts: risk of damage to the generating set.