rammable Thermostat
Installer Setup
Number
Installer Setup
Name
Settings
0120
Date
(Year Upper)
It cannot be changed.
0130
Date
(Year Lower)
Select last two digits of current calendar year (08 for year 2008, etc)
0140 Date (Month) Select number of current calendar month (1-12)
0150 Date (Day) Select number of current calendar date (1-31)
0160 Schedule Options
0-Non-programmable
4-7-day programmable(factory setting)(when it is changed, the schedule need
to be reprogrammed)
0320
Display temperature in
°F or °C
0-°F setting (factory setting)
1-°C setting
0330 Daylight savings time
1-Daylight Savings function is enabled.
0-Daylight Savings is disabled.
0500 Furnace air filter
0-off (factory setting)
1-10 fan run time days(about one month)
2-30 fan run time days(about three months)
3-60 fan run time days(about six months)
4-90 fan run time days(about nine months)
5-120 fan run time days(about one year)
6-365 fan run time days(about three years)
T
able 5. User Setup Settings.
60
STS11 Touchscreen Pro
g
rammable Thermostat
T
able 5. User Setup Settings. (CONTINUED)
Installer Setup
Number
Installer Setup
Name
Settings
0510
Humidifier Pad
Replacement
Reminder
0-humidifier pad replacement reminder off.
1-90 calendar days.
2-180 calendar days.
3-365 calendar days.
0520
UV Lamp Replacement
Reminder
0-UV lamp replacement reminder off.
1-365 calendar days.
0540
Number of schedule
periods available
2-two (WAKE and SLEEP)
4-four (WAKE, DAY, EVENING, SLEEP) factory setting
0640 Clock format
12-12-hour clock(factory setting)
24-24-hour clock
0670 Screen lockout
0-all keys available; screen is unlocked (factory setting)
1-screen is partially locked. All key functions locked except Temperature Up
and Down keys and Cancel key.
2-screen is fully locked