INSTALLATION
MANUAL
Section 4: STARTUP
5) Press the GYRO ON/OFF Button on Display. The RED LOCK ICON and the PROGRESS BAR
will appear and be RED until the GYRO is at speed, then stabilization can begin.
6) The sea water pump should have started when the ON/OFF button on the display was
depressed. Confirm pump operation and flow rate, if practical. Required flow is 4 GPM (15 LPM)
minimum and 8 GPM (30 LPM) maximum.
7) Verify that there are no ALARMS present. If an ALARM is present it will be displayed.
8) When the PROGRESS BAR turns GREEN from RED the GYRO can be placed in SEA mode. Depress
the LOCK/UNLOCK Button and the GYRO will be free to move and precession can occur.
9) Verify that there are no alarms. If an ALARM is present it will be displayed.
10) Press the LOCK/UNLOCK Button to go from SEA to LOCK mode. Then press the GYRO
ON/OFF Button to power the GYRO down.