J English I
OPERATION
TECHNICAL SPECIEICATIONS
Voltage: 120 volts AC
Output: 1400 watts
Temperature:
Step 1 : 120 ° F
Step 2: 800 ° F
Step 3: 1000 ° F
Airflow:
Step 1 : 17.6 cfm
Step 2: 11.3 cfm
Step 3: 17.6 cfm
Weight: 29 oz.
with cord and plug
MAINTENANCE AND CARE
Always disconnect the power plug before
performing any work on the tool.
The air inlets on the rear sides of the tool must
be kept free of dust and dirt. Avoid using the tool
in a dusty environment as dust inside the tool will
cause the tool to malfunction.
The power cord will be damaged if touched by
the hot metal nozzle or accessories.
The tool requires no lubrication.
The operation of any power tool can result in foreign objects being thrown into ]
your eyes, which can result in severe eye damage. Before commencing power
tool operation, always wear safety goggles or safety glasses with slide shields
and a full face shield when needed. We recommend Wide Vision Safety Mask
for use over spectacles or standard safety glasses with side shields, available
at Sears Retail Stores.
Page 6
OPERATION
"BEFORE START-UP"
Read this entire manual before turning the tool
on.
Be sure you have a 120 Volt, 60 Hz, AC power
source.
Be sure the switch is in the "off" position.
!
Fig. 1
Hot Air Outlet Nozzle
Protective Cover
Housing
Wide, flared side for secure stand
Switch:
Four-position control switch
®Warm air/co Hot air Step II
• Hot air Step Ill
Grip
Heel of grip,
for secure stand
Power cord with
anti-kink reinforcing sleeve
To operate the Heat Gun, plug the cord The unit may be used in a hand held
into a 120 Volt, 60 Hz, AC, power source, position (Fig. 1)or in a hands free upright
Be sure the power switch is in the OFF position (Fig. 2) on a fiat level surface.
position. When using the unit in the upright posi-
The Heat Gun has a four position power tion, the tool should be clamped to the
switch (see ,,switch" above). Be sure the surface and the power cord should be
unit is pointed away from yourself and placed in a position to _revent tripping
materials before turning unit on. over the cord.
Page 7