14
SEASTAR Hydraulics
VENT PLUG - Part No. HP6126
SUPPLIED WITH SEASTAR HELM PUMP
MUST BE USED WITH HELM PUMP ON ALL SINGLE
STEERING STATION SYSTEMS.
MUST BE USED ON UPPERMOST HELM PUMP ON
MULTI STEERING STATION SYSTEMS.
NON-VENT PLUG - Part No. HP6000
MUST BE USED ON ALL HELM PUMPS OTHER THAN
UPPER MOST HELM PUMP ON MULTI STEERING
STATION SYSTEMS.
THIS NON-VENT PLUG IS SUPPLIED WITH ADDITIONAL
STATION FITTING KIT NO. HF5501 AND HF5502.
Figure 7.
Fill Plugs for SeaStar
Helms
In an emergency, SeaStar EPS Fluid, any MD-3/4 rated ATF or MIL-
PRF-5606H equivalent fluid that is filtered through a fine mesh
screen can be used. The system MUST be thoroughly flushed as
soon as possible with genuine SeaStar Steering Fluid after using an
emergency fluid.
In an EXTREME emergency, any non-toxic, non-flammable fluid that is
filtered through a fine mesh screen may provide temporary steering.
Use of non-standard fluids will require an immediate and complete
system flush using approved fluids, by an approved steering technician.
SeaStar Hydraulic Steering Fluid can be used in Hynautic, BayStar
and BayStar Plus
steering systems.
Help protect your boating environment by ensuring that all used oil
is disposed of properly.
Never fill or mix brake fluids, trigycerides or polyalkylene glycols
within a hydrauilic steering system.
NOTICE
NOTICE
WARNING
AUTOPILOT PUMP