Autopilot Pump
17
3.1.5
Holding the cylinder body (Outboard Front Mount cylinder) or rod
(Side Mount
cylinder) to prevent the body/rod from moving, turn the
steering wheel
clockwise until a steady stream of air free oil comes out
of the bleeder.
Run SeaStar Autopilot pump continuously in the same direction
you have been turning for a minimum of 2 minutes.
While continuing to turn the wheel close the bleed fitting for your
application and let go of the cylinder body/rod.
Torque all cylinder bleed fittings to 180 in-lbs.
TURN CLOCKWISE
CLOSE LEFT SIDE
BLEEDER
TURN CLOCKWISE
CLOSE
RIGHT SIDE
BLEEDER
Outboard Front Mount & HC5332-2 Cylinder
Side Mount / Splashwell Mount Cylinder
All Balanced Cylinder. Inboard & Sterndrive Cylinders
TURN CLOCKWISE
CLOSE
RIGHT SIDE
BLEEDER
Prior to operating system,
perform Oil Level System
Check, refer to page 20.
CAUTION
3.1.6
Open Autopilot pump reservoir bleed fitting. Refer to figure 9.
Wait approximately 30 seconds while reservoir purges. Fluid may
or may not exit bleeder at this time depending on individual
configuration.
Close reservoir bleed fitting and torque to 180 in-lbs.
RESERVOIR BLEED FITTING
Figure 9.
AUTOPILOT PUMP