Category | Test Equipment |
---|---|
Type | Solar PV Tester |
Voltage Measurement Range | 0 to 1000 V DC |
Voltage Measurement Accuracy | ±1% ±2 digits |
Current Measurement Range | 0 to 15 A DC |
Current Measurement Accuracy | ±1% ±2 digits |
Insulation Resistance Test Voltages | 250 V, 500 V, 1000 V |
Continuity Measurement Resolution | 0.01 Ω |
Open Circuit Voltage (Voc) Test | Yes |
Short Circuit Current (Isc) Test | Yes |
Polarity Test | Yes |
Data Logging | Yes |
Wireless Connectivity | No |
Operating Temperature | -10°C to +50°C |
Storage Temperature | -20°C to +60°C |
Display | LCD |
Weight | 0.5 kg |
Lists items included in the PV150 test kit.
Lists additional accessories available for purchase.
Identifies front and end view components of the PV150 unit.
Explains the icons and indicators shown on the PV150's LCD screen.
Instructions on how to turn the PV150 unit on.
How the PV150 checks and indicates battery status.
Details on performing Rpe measurements, including test lead null, resistance, and voltage.
How to automatically perform a sequence of tests on a PV installation.
How to store measurement results in the PV150's memory.
How to retrieve stored measurement results from the PV150's memory.
How to erase all stored measurement data from the PV150.
Procedure for measuring the DC operating current of a PV installation.
Procedure for measuring the DC operating power of a PV installation.
How to configure the PV150's auto shutdown timer.
Explains common error messages and their remedies.
Steps to connect and pair the PV150 with the Solar Survey 200R.
Steps to disconnect and unpair the PV150 from the Solar Survey 200R.
How to activate transmit mode on the Survey 200R for data sharing.
How the PV150 displays irradiance from a paired Survey 200R.
Instructions for transferring stored data from the PV150 to a computer.
Electrical specifications for measuring Open Circuit Voltage.
Electrical specifications for measuring Short Circuit Current.
Electrical specifications for Earth Continuity testing.
Electrical specifications for Insulation Resistance testing.
Electrical specifications for Rpe Voltage measurements.
Electrical specifications for measuring Operating Current with a clamp.
Electrical specifications for measuring DC Power with a clamp.
Safety precautions before performing maintenance on the PV150.
Conditions under which safe operation cannot be assumed, requiring securing the unit.
Instructions on how to clean the external case of the PV150.
Step-by-step guide for replacing the batteries in the PV150.
Step-by-step guide for replacing the fuse in the PV150.
Information on recommended service and calibration intervals.
List of available spare parts and their part numbers.