FP Time Out
0~60s can be set, default setting: 30s, used for enroll fingerprint: to detect if press
fingerprint after command, time out will exit to enroll.
For setting “0” means no time out for judging.
Standby
0~60s, Device will enter into standby mode if without any operation during the setting time.
The device will be activated if press a finger or a proximity card or there is
communication command from PC.
For setting "0" means no sleep mode, default setting: 60 seconds.
Security level
1~5 levelsdefault setting is 3level 1 is the most high security level.
After setting the above parameter, click “Add” will register the device to software.
2). To Set/Modify device parameters
To select the device in the Device List, after inputting the above parameters.
If using USB communication mode, click “Set Information” to keep setting successfully.
If using RS485 communication mode, make sure the consistency of Device ID and baud rate with the
present device.
After setting successfully, device will working as the setting parameters.
3). To get device information
To select the device in the Device List, click “Get Information”, will get the device parameters and
total enrolled user data, fingerprint users, cardholders and the device’s version info.
Note
1. Please make sure Device ID & Baud Rate are correct when get information from device by
RS485.
2. If no device ID & baud rate, please choose USB to get the information first on condition
that know communication password.
4). To Initialize the Device
To Select the device in the Device List, click “Device Init”all the enrolled user information will be
deleted , and resume to the following default parameters:
Note: Device Initialization will not delete communication password.
Name
Default setting
Device ID
0
Baud rate
9600BPS
Wiegand mode
Wiegand26
Verification mode
Card or fingerprint
Security level
3